Clearscan Tm Current Groups; Clearscan Tm Band - Electro-Voice Telex RE-1 Operating Instructions Manual

Electrovoice re 1 microphone system: user guide
Hide thumbs Also See for Telex RE-1:
Table of Contents

Advertisement

TM
ClearScan
Cur rent Group
ClearScan
TM
Current Group scans channels within the cur -
rently se lected frequency group and displays the chan nels that
are clear of in terference.
Press [SET] to initiate
Press [MENU] to abort
After scanning the cur rently se lected group, ClearScan
display the chan nels that are free of in terference. These clear
channels are displayed on the right half of the screen. The
channels are ranked according to noise; the channel with the
least amount of in terference is presented first.
The [UP] and [DOWN] but tons may be used to se lect a differ-
ent clear channel within the cur rently se lected group.
Press [SET] to place the re ceiver on the cur rently se lected
channel and re turn to the Operating Screen.
Press [MENU] to re turn to the Operating Screen with the re-
ceiver set to the Group, Channel and Fre quency it was on
prior to ex e cut ing ClearScan
TM
ClearScan
Band
ClearScan
TM
band con tin u ously scans all fre quen cies within
the bandwidth of the re ceiver. The scan is started at the fre-
quency the receiver is on and pro ceeds in 200 kHz in crements
on ei ther side un til the whole band is scanned. The scan is re-
peated un til ended by the user.
Press [SET] to initiate
Each fre quency is scanned con tinuously within the band; the
highest read ing on each fre quency is stored to give a
worse-case read ing as long as the scan is be ing done.
Pressing [SET] ends the scan. Af ter scanning, ClearScan
places the 16 best frequencies in the band into 'scanned' group
21s. This group is stored to prevent accidental era sure. The
best fre quency is placed at channel one and displayed.
The [UP] and [DOWN] but tons may be used to se lect the next
clear chan nel at least 200 kHz above or be low the currently
dis played fre quency.
Press [SET] to ac cept cur rently se lected fre quency and re turn
to the Operating Screen.
Press [MENU] to re turn to the Operating Screen with the re-
ceiver set to the Group, Channel and Fre quency it was on
prior to ex e cut ing ClearScan
TM
.
TM
.
Gr o u p 1 2 u
OK ? =[ S E T ]
TM
will
P r e v
N E X T
Ch a n .
Gr o u p 2 1 s
P r e v
TM
OK ? =[ S E T ]
4-5
T M
CL E A R S CA N
0 4
0 3
1 5
0 1
0 5
0 8
0 2
1 6
Fig ure 13
ClearScan
TM
Cur rent Group
T M
CL E A R S CA N
S c a n n i n g B a n d
0 1
7 2 8 . 4 7 5
N e x t
Fig ure 14
ClearScan
TM
Band
0 9
MH z

Advertisement

Table of Contents
loading

Table of Contents