Deleting A Time Phase; Setting The Heating Curve - Viessmann VITOLIGNO 300-H Operating Instructions For The System User

Heating system with ecotronic weather-compensated, digital boiler and heating circuit control unit
Table of Contents

Advertisement

Setting the time program
12. |/~ to set the start time.
13. d
to confirm.
14. |/~ to set the end time.
15. d
to confirm.
16. To adjust the beginning and end of
further time phases, proceed as
described in steps 10 to 15.

Deleting a time phase

1. Set the time for the end point to the
same time that was set for the start
point.
The display shows "- - : - -".
2. Press d to confirm.

Setting the heating curve

In the "Automatic" operating program,
the control unit automatically determines
the average set temperature of the heat-
ing water buffer cylinder. It takes into
account the selected heating curve and
the outside temperature.
Press the following keys:
1. å
for the "Extended menu".
Heating water buffer cylinder
(cont.)
Example shown:
■ Time program for Monday to Friday
("Mo-Fr")
■ Time phase !:
From 04:30 to 08:30 h
■ Time phase ?:
From 16:30 to 23:00 h
!
0 2 4 6 8 10 12 14 16 18 20 22 24
1
04:30 - 08:30
2
16:30 - 23:00
Select with
Time program
0
2
4
6
8 10 12 14 16 18 20 22 24
? - -:- - - - -:- -
§ - -:- - - - -:- -
Change with
2. |/~ to select "Buffer".
3. d
4. |/~ for "Heating curve".
5. d
6. |/~ for "Slope"
?
Mo-Fr
I
Std
I
Std
Mo-Su
---
u
---
u
(
to confirm.
to confirm.
or "Level".