Deleting A Time Phase; Resetting Time Phases To Factory Settings - Viessmann VITOLIGNO 300-H Operating Instructions For The System User

Heating system with ecotronic weather-compensated, digital boiler and heating circuit control unit
Table of Contents

Advertisement

Setting the time program
Example shown:
■ Time program for Monday to Friday
("Mo-Fr")
■ Time phase !:
From 04:30 to 06:30 h
■ Time phase ?:
From 15:30 to 20:30 h
!
DHW
Mo-Fr
0
2
4
6
8 10 12 14 16 18 20 22 24
04:30 - 06:30
!
15:30 - 20:30
?
Select with

Deleting a time phase

1. Set the time for the end point to the
same time that was set for the start
point.
The display shows "- - : - -".
2. Press d to confirm.

Resetting time phases to factory settings

Note
The time phases for DHW heating are
only reset to factory settings when you
reset all settings for "DHW".
(cont.)
?
HC1
Std
u
Std
u
(
Example:
You want to set the same time program
for every day except Monday:
Select the period "Monday–Sunday"
and set the time program.
Then select "Monday" and set the time
program for this.
DHW time program
0
2
4
6
8 10 12 14 16 18 20 22 24
? - -:- - - - -:- -
u
§ - -:- - - - -:- -
u
Change with
The steps for resetting to factory settings
can be found on page 49.