Troubleshooting
Fault codes
(cont.)
Displayed fault
System characteristics
code
b0
Burner locked out
b1
Control mode as per deliv-
ered condition
b5
Control mode as per deliv-
ered condition
b7
Burner locked out
b8
Burner locked out
bA
Mixer regulates to 20 °C flow
temperature.
bb
Mixer regulates to 20 °C flow
temperature.
bC
Control mode without remote
control
bd
Control mode without remote
control
bE
Control mode without remote
control
bF
Control mode
C1
Control mode
C2
Control mode
Cd
Control mode
CF
Control mode
d6
Control mode
d7
Control mode
82
Cause
Short circuit, flue gas tem-
perature sensor
Communication error, pro-
gramming unit
Internal error
Boiler coding card fault
Lead break, flue gas tem-
perature sensor
Communication error, mix-
er M2 extension kit
Communication error, mix-
er M3 extension kit
Communication error,
Vitotrol remote control,
heating circuit 1 (without
mixer)
Communication error,
Vitotrol remote control,
heating circuit 2 (with mix-
er)
Communication error,
Vitotrol remote control,
heating circuit 3 (with mix-
er)
Wrong LON communica-
tion module
EA1 extension communi-
cation error
Communication error, so-
lar control module or
Vitosolic
Communication error,
Vitocom 100 (KM-BUS)
Communication error,
LON communication mod-
ule
Input DE1 at
EA1 extension reports a
fault.
Input DE2 at
EA1 extension reports a
fault.
Measures
Check flue gas temperature sen-
sor.
Check connections and replace
programming unit if necessary.
Replace control unit.
Plug in boiler coding card or re-
place if faulty.
Check flue gas temperature sen-
sor.
Check mixer extension kit connec-
tions and code.
Check mixer extension kit connec-
tions and code.
Check connections, lead, coding
address "A0" and remote control
settings (see page 97). For wire-
less remote control units: Check
connection; place remote control
close to the boiler.
Check connections, lead, coding
address "A0" and remote control
settings (see page 97). For wire-
less remote control units: Check
connection; place remote control
close to the boiler.
Check connections, lead, coding
address "A0" and remote control
settings (see page 97). For wire-
less remote control units: Check
connection; place remote control
close to the boiler.
Replace LON communication mod-
ule.
Check the connections.
Check solar control module or
Vitosolic.
Check connections, Vitocom 100
and coding address "95".
Replace LON communication mod-
ule.
Remedy fault at affected appliance.
Remedy fault at affected appliance.