Viessmann Vitoladens 300-C Installation And Service Instructions Manual page 75

Oil condensing boiler with integral boiler control unit
Hide thumbs Also See for Vitoladens 300-C:
Table of Contents

Advertisement

Code 2
(cont.)
Parameter address
With heating circuit pump logic function:
b5:...
Heating circuit pump "OFF"
7
RT
8
RT
Coding in the delivered condition
C5:20
Electronic minimum flow tempera-
ture limit 20 °C
C6:74
Electronic maximum flow tempera-
ture limit set to 74 °C
d3:14
Heating curve slope = 1.4
d4:0
Heating curve level = 0
d5:0
External operating program
changeover switches operating
program to "Constant operation at
reduced room temperature" or
"Standby mode"
d6:0
Heating circuit pump stays in con-
trol mode at "External blocking"
signal.
d7:0
Heating circuit pump stays in con-
trol mode at "External demand"
signal.
d8:0
No operating program changeover
via EA1 extension
E1:1
Do not adjust!
E2:50
With remote control: No display
correction of the actual room tem-
perature
E5:0
Without external variable speed
heating circuit pump
> RT
1 K
actual
set
> RT
2 K
actual
set
Heating circuit pump "ON"
RT
< RT
actual
set
RT
< RT
actual
set
Possible change
C5:1
Minimum limit adjustable from 1 to
to
127 °C (limited by boiler-specific pa-
C5:127
rameters)
C6:10
Maximum limit adjustable from 10 to
to
127 °C (limited by boiler-specific pa-
C6:127
rameters)
d3:2
The heating curve slope is adjusta-
to
ble from 0.2 to 3.5 (see page 52)
d3:35
d4:–13
The heating curve level is adjustable
to
from
d4:40
d5:1
The external operating program
changeover switches to "Constant
operation at standard room tempera-
ture" (subject to coding addresses
"3A", "3b" and "3C")
d6:1
Heating circuit pump is switched off
at "External blocking" signal (subject
to coding addresses "3A", "3b" and
"3C")
d6:2
Heating circuit pump is switched on
at "External blocking" signal (subject
to coding addresses "3A", "3b" and
"3C")
d7:1
Heating circuit pump is switched off
at "External demand" signal (de-
pending on coding addresses "3A",
"3b" and "3C")
d7:2
Heating circuit pump is switched off
at "External demand" signal (de-
pending on coding addresses "3A",
"3b" and "3C")
d8:1
Operating program changeover via
input DE1 at EA1 extension
d8:2
Operating program changeover via
input DE2 at EA1 extension
d8:3
Operating program changeover via
input DE3 at EA1 extension
E2:0
Display correction
to
to
E2:49
Display correction
E2:51
Display correction +0.1 K
to
to
E2:99
Display correction +4.9 K
E5:1
With external variable speed heating
circuit pump (automatic recognition)
Codes
2 K
3 K
13 to 40 (see page 52)
5 K
0.1 K
75