Siemens SIMOTICS M-1PH3 Manual page 97

Main motors
Table of Contents

Advertisement

These drives typically operate at a specific operating point and are dimensioned for a base
load. The base load torque must lie below the S1 characteristic curve. An overload rating is
provided for transient overloads (for example, during acceleration). The overload current
must be calculated relative to the required overload torque. The peak torque must lie below
the voltage limiting characteristic curve.
Duty cycles with a varying ON period
Besides continuous duty cycles (S1), standard intermittent duty cycles (S6) are defined for
duty cycles with a varying ON period. This is a mode of operation consisting of a series of
similar cycles, with each one comprising one time period with a constant load and one idle
time period. There is no pause.
The figure below shows the S6 duty cycle for continuous duty with an intermittent load.
The following fixed variables (overload factors) are usually applied to the relative ON period:
• S6-40%
• S6-25%
• S6-15%
For more information about the overload factors for the corresponding intermittent duty type
(S6) referred to the continuous duty type (S1), see Section "Overload factors for intermittent
duty types (S6) (Page 126)".
Note
S3 duty cycle
The overload factors for continuous duty with an intermittent load (S6) can also be applied to
the S3 intermittent duty type (S3-40%, S3-25%, or S3-15%) for the 1PH3 motors.
1PH3 main motors
Equipment Manual, 01/2021, A5E43087278-004
Configuration
7.2 Procedure when engineering
95