Code to causes of faults and remedial measures
Code
A
B
C
D
F
E
I
J
K
L
M
N
O
P
Q
R
If the fault still cannot be resolved after applying the measures specified above, contact the
manufacturer or Siemens Service Center.
1PH3 main motors
Equipment Manual, 01/2021, A5E43087278-004
Cause of fault
Overload
Interrupted phase in the supply
cable/motor winding
Interrupted phase in the feeder
cable after switching on
Converter output voltage too
high, frequency too low
Winding short circuit or phase
short circuit in stator winding
Stator winding incorrectly con-
nected
Heat dissipation obstructed by
deposits
Cooling air inlet/outlet is
blocked by foreign bodies
Fan motor does not start
Insufficient shielding for motor
and/or encoder cable
Drive controller gain too high
Rotating parts are grinding
Foreign bodies in the motor
Bearing damage
Rotor not balanced
Rotor out of true, shaft bent
Poor alignment
Coupled machine not balanced
Mechanical shocks from cou-
pled machine
Uneven gearbox operation
Remedial measures
Reduce load
Check the converter and supply cables/measure the wind-
ing resistances and insulation resistances, repair after con-
sultation with manufacturer
Check the converter and supply cables/check the winding
resistances
Check the converter settings, perform automatic motor
identification
Measure the winding resistances and insulation resistances,
repair after consultation with manufacturer
Check winding connection
Clean the drive surfaces. Ensure that the cooling air can
flow in and out unimpeded
Remove the blockage. Ensure that the cooling air can flow
in and out unimpeded
Check the function of the fan motor
Check the shielding and grounding
Adjust the controller
Determine cause and adjust parts concerned
Send to manufacturer for repair
Send to manufacturer for repair
Decouple rotor and rebalance
Consult the manufacturer
Align machine set, check coupling
Rebalance coupled machine
Inspect coupled machine
Repair the gearbox
Operation
9.1 Faults
111

Advertisement

Table of Contents
loading

Table of Contents