Response To Poor Reaction/No Reaction Of The Ultrasonic Motion Sensor - Canon C5500 Series Troubleshooting Manual

Table of Contents

Advertisement

Response to poor reaction/no reaction of the Ultrasonic Motion
Sensor
For CE
[Symptom]
Ultrasonic Motion Sensor may react poorly, or does not react.
[Cause]
Due to installation failure, aforementioned symptom may occur .
[Remedy]
1) Confirm that the motion sensor PCB assembly is installed correctly.
- Make sure the black sponge [a] is not overhanging inside the enclosure part [b].
- Make sure the screw[c] is firmly screwed in.
- The motion sensor PCB assembly is fixed at the locking position [d].
- The connector [e] is connected properly.
2) If the motion sensor PCB assembly is not installed correctly, re-install it correctly.
Target S/N of the Ultrasonic Motion Sensor
NOTE: All iR-ADV 4500 Series/iR-ADV C355 Series/iR-ADV C3500 Series are target machines.
iR-ADV C5500 Series
iR-ADV C5560I 120V
iR-ADV C5560I TW 120V
iR-ADV C5560I 120V G
iR-ADV C5550I 120V
iR-ADV C5550I TW 120V
iR-ADV C5550I 120V G
iR-ADV C5540I 120V
iR-ADV C5540I TW 120V
iR-ADV C5540I 120V G
iR-ADV C5535I 120V
iR-ADV C5535I TW 120V
iR-ADV C5535I 120V G
iR-ADV C5560 CN 220V
iR-ADV C5560I EUR 230V
iR-ADV C5560I 230V
iR-ADV C5560I LTN 230V
iR-ADV C5550 CN 220V
Model
Target Serial Number
XLA
XGW
XLF
XLG
XGY
XLH
XLJ
XHA
XLK
XLN
XJA
XLP
XGA
XMD
XKS
XLQ
XGN