Response to poor reaction/no reaction of the Ultrasonic Motion
Sensor
For CE
[Symptom]
Ultrasonic Motion Sensor may react poorly, or does not react.
[Cause]
Due to installation failure, aforementioned symptom may occur .
[Remedy]
1) Confirm that the motion sensor PCB assembly is installed correctly.
- Make sure the black sponge [a] is not overhanging inside the enclosure part [b].
- Make sure the screw[c] is firmly screwed in.
- The motion sensor PCB assembly is fixed at the locking position [d].
- The connector [e] is connected properly.
2) If the motion sensor PCB assembly is not installed correctly, re-install it correctly.
Target S/N of the Ultrasonic Motion Sensor
NOTE: All iR-ADV 4500 Series/iR-ADV C355 Series/iR-ADV C3500 Series are target machines.