Omron E5CSZ Manual page 3

Easy setting using dip switch and simple functions in din 48x48 mm-size temperature controllers
Table of Contents

Advertisement

Characteristics
Setting accuracy
Indication accuracy
(ambient temperature of 23 ° C)
Influence of temperature
Influence of voltage
Hysteresis (for ON/OFF control)
Proportional band (P)
Integral time (I)
Derivative time (D)
Alarm output range
Control period
Sampling period
Insulation resistance
Dielectric strength
Vibration
Malfunction 10 to 55 Hz, 20 m/s
resistance
Destruction 10 to 55 Hz, 0.75-mm single amplitude for 2 hr each in X, Y, and Z directions
Shock resistance
Malfunction 100 m/s
Destruction 300 m/s
Life expectancy
Electrical
Weight
Degree of protection
Memory protection
EMC
Approved standards
Conformed standards
Note: 1. The following exceptions apply to thermocouples.
• L: ±2 ° C ±1 digit max.
2. The following exceptions apply to platinum resistance thermometers.
Input set values 0, 1, 2, 3 for E5CSZ: 0.5% FS ±1 digit max.
Input set value 1 for E5CSZ: 0.5% FS ±1 digit max.
Electrical Life Expectancy Curve for Relays (Reference Values)
500
300
100
50
30
10
5
E5CSZ
250 VAC, 30 VDC
3
(resistive load)
cosφ = 1
1
0
1
2
3
Thermocouple (See note 1.):
Platinum resistance thermometer (See note 2.): (±0.5% of indication value or ±1 ° C, whichever is greater) ±1 digit max.
Thermocouple inputs:
Platinum resistance thermometer inputs: (±1% of PV or ±2 ° C, whichever is greater) ±1 digit max.
0.1% FS for multi-input (thermocouple/platinum resistance thermometer) models
1 to 999 ° C (automatic adjustment using auto-tuning/self-tuning)
1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning
1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning)
Absolute-value alarm: Same as the control range
Other:
0% to 100% FS
0.2 ° C or ° F (fixed)
Alarm hysteresis:
2/20 s
500 ms
20 M Ω min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min between current-carrying terminals of different polarity
2
for 10 min each in X, Y, and Z directions
2
min., 3 times each in 6 directions
2
min., 3 times each in 6 directions
100,000 operations min. (relay output models)
Approx. 120 g (Controller only)
Front panel: Equivalent to IP50; Rear case: IP20; Terminals: IP00
EEPROM (non-volatile memory) (number of writes: 1,000,000)
EMI Radiated:
EMI Conducted:
ESD Immunity:
Radiated Electromagnetic Field Immunity:
Conducted Disturbance Immunity:
Noise Immunity (First Transient Burst Noise): EN 61000-4-4
Burst Immunity:
Surge Immunity:
Voltage Dip/Interrupting Immunity:
UL 61010C-1 (listing)
CSA C22.2 No.1010-1
EN 61326, EN 61010-1, IEC 61010-1
VDE 0106 Part 100 (finger protection), when the terminal cover is mounted.
4
5
6
Switching current (A)
(±0.5% of indication value or ±1 ° C, whichever is greater) ±1 digit max.
(±1% of PV or ±4 ° C, whichever is greater) ±1 digit max.
EN 55011 Group 1 Class A
EN 55011 Group 1 Class A
EN 61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
EN 61000-4-3: 10 V/m (80-1000 MHz, 1.4-2.0 GHz amplitude modulated) (level 3)
10 V/m (900 MHz pulse modulated)
EN 61000-4-6: 3 V (0.15 to 80 MHz) (level 2)
2 kV power-line (level 3), 1 kV I/O signal-line (level 3)
EN 61000-4-5: Power line:
Output line (relay output): Normal mode 1 kV; Common mode 2 kV
EN 61000-4-11 0.5 cycle, 100% (rated voltage)
Temperature Controllers
Normal mode 1 kV; Common mode 2 kV
E5CSZ
3