SW2 used for factory reset
Position D of rotary switch SW2 is used for factory reset. All other positions of the rotary switch are not used in this
release.
Factory reset
1. Switch the position of the rotary switch SW2 to position D.
2. Press and release SW3 Reset button.
3. Wait until LEDs DS4 and DS8 flash. Factory reset is successful if DS4 and DS8 flash in a sequence of two flashes
in quick succession then pause and repeat continuously. If there are more than two quick flashes in the sequence,
the factory reset has failed.
4. Switch rotary switch SW2 to position 0.
5. Press and release SW3 Reset button.

Ports and connectors

See
Figure 4
on
Page 9
J5
The second RJ45 port (J5) used for connection to the iSTAR Ultra LT when mounted in the same enclosure. If this use
case is being implemented, two IP addresses are needed: one for the IP-ACM and another for the iSTAR Ultra LT.
Caution: Do not plug this port into the same network as J1 or a loopback will occur.
DO NOT PLUG INTO THE SAME NETWORK AS PORT 1 OR A LOOPBACK WILL OCCUR!
Specific requirements for the second RJ45 port are:
■ Full duplex wiring
■ 10/100 speed (Gigabit Ethernet not provided)
■ Power over Ethernet (PoE) not provided on this port
P1
This port supports local power of 12 VDC or 24 VDC, 25.5W max. However, the maximum combined output limit for
readers and locks is 17W (+/-10 %). See
requirements.
P3 and P4
Figure 5
on
Page 11
illustrates the wiring for a Wiegand reader on the IP-ACM v2.
10
for ports and connectors on the IP-ACM v2.
Table 4
on
Page 5
for more information regarding power and wiring