Starting a New Job
(or Refilling the Material Cup)
1.
Engage trigger lock and put prime/spray valve UP to
release pressure.
ti18866a
ti14994a
2. Install material cup liner, fill with material, and
thread onto sprayer.
3. To fill sprayer with fluid, disengage trigger lock and
trigger sprayer for 10 seconds. Then release trigger
and put prime/spray valve DOWN to spray position.
ti18874a
ti14995a
4. Reverse spray tip to UNCLOG position, pull trigger
and release.
ti14991a
ti14991a
5. Put prime/spray valve UP to release pressure. Then
rotate spray tip back to spray position.
NOTE: Failure to perform this operation could result
in poor spray pattern.
12
ti16700a
ti14999a
ti15474a
ti16716a
ti15418a
ti14985a

Starting a New Job (or Refilling the Material Cup)

If sprayer fails to prime, try one of the steps
below:
1. Use the Pump Armor storage/startup tool to clean
the inlet valve fitting. See Storage, page 18.
ti18868a
2. Clean air vent holes or the air vent valve,
depending on model. See Shutdown and Clean-
ing, page 16.
Remove air vent valve, clean, and reinstall.