APPROVED COOLANTS
The approved and preferred coolants
for Series 60 engines are listed in Table
12. Once installed, these coolants
should be maintained according to the
procedures
discussed
Maintenance.
NOTICE:
Required specifications for water,
ethylene glycol, propylene glycol,
inhibitor packages, and inhibitor con-
centration are included in this sec-
tion. To avoid possible engine
damage from inadequate or over-
concentrated coolant, this informa-
tion should be read thoroughly
before the coolant is replaced.
Coolant Fill Option
Ethylene Glycol & Water + Corrosion Inhibitors 1
Commercial Equivalent of DDC Power Cool
Propylene Glycol & Water
+ Corrosion Inhibitors
Ethylene Glycol & Water+ NOAT Inhibitors
Water Only + Corrosion Inhibitors 2
Water Only + NOAT Inhibitors 2
1 Preferred Coolant
2 Water-only coolant systems offer no freeze protection and should not be used where ambient temperatures
can fall to 32°F (0°C).
Table 12. Initial Fill Coolant Options
Ethylene Glycol/Water +
SCA Inhibitor/Propylene
Glycol/Water + SCA Inhibitor
These products are available as fully
formulated, Phosphate-Free, Extended
Service Interval (ESI) coolants. They are
under
commercially available from Detroit
Diesel (recommended) and other manu-
facturers, as either a concentrated
antifreeze or as a pre-mixed antifreeze.
The pre-mixed antifreeze is ready for
use, while the concentrated coolant
must be mixed with water prior to use.
Product
DDC Power Cool
Fully Formulated TMCRP-329 Type A
Antifreeze & Water
Fully Formulated TMC RP-330 Type
A Antifreeze & Water
DDC Power Cool Plus
Water + DDC Power Cool 3000
Water + DDC Power Cool Plus 6000
49