14 ALARM MANAGEMENT

Failure is signalled by means of the following procedure:
1) sound warning (beep),
2) lighting up of one of the following icons:
3) in the case of an alarm, the stove will be extinguished,
4) holding the "cancel" button
the alarm:
CODE OF
ALARM/
MESSAGE
Control keyboard damaged
E001
Remote control signal not received
E002
Connection interrupted
E004
Ignition failed
E101
Pellet sensor alarm
E105
*
Safety alarm
E108
Pressure alarm or tripping of circuit
E109
breaker
Malfunction of temperature sensor
E110
Malfunction of smoke sensor
E111
Insufficient pellet level (flashing icon)
A001
Warning concerning planned
A002
maintenance (flashing icons)
Low battery
A004
Malfunction of pressure sensor
A007
(flashing icon)
----
Cleaning the stove
----
Ignition failed
* Only in the case of models equipped with safety micro-switches in the door or on the container's cover.
After the message is checked, the alarm can be cleared by
pressing the ignition/extinguishing button
seconds.
If code "E108" or "E109" is displayed, manually restart
the thermostat located on the rear of the stove, then
clear the alarm (fig. 14.1) (this activity must be performed
according to the guidelines of the authorised seller). The
stove can be reignited.
,
displays the code of
DESCRIPTION
for several
fig� 14�1
POTENTIAL CAUSES
Damage to control keyboard
Damage to control keyboard
Cutting off or disconnection of cable connecting
the card to the control keyboard.
Ignore this alarm if it is displayed during change of
configuration.
No pellet
Pellet quality
Malfunction of ignition system
Dirty brazier
Pellet sensor damaged or disconnected
Open door or funnel
Dirty smoke extraction system
Wear of gaskets
Insufficient air for combustion
Overheating of pellet container
Damaged air sensor
Damaged smoke temperature sensor
Pellet running out
The stove requires regular maintenance, which
must be performed by specialised personnel.
The back-up battery (mod. CR2032) on the
electronic board is low
Malfunction of pressure sensor or card
Dirty combustion chamber, brazier or smoke
extraction system.
Pollution or disconnection of pressure reading
cables.
Pollution of inlet for combustion air.
No pellet; igniter damaged; worn gasket; improper
brazier positioning
Before proceeding with a new ignition, check that:
• the stove is cold
• the brazier is clean and free of any residue of ash or
granules
• the brazier is correctly positioned in its seat
• the doors of the firebox and the tank are perfectly
closed