Specifications; Electrical And Refrigerant Data - Hoshizaki KM-470AJ Instruction Manual

Modular crescent cuber
Hide thumbs Also See for KM-470AJ:
Table of Contents

Advertisement

I. Specifications
A. Electrical and Refrigerant Data
The nameplate provides electrical and refrigerant data. The nameplate is located on the left
panel. For certification marks, see the nameplate.
We reserve the right to make changes in specifications and design without prior notice.
1. KM-470A_J/KM-470A_J-S
Model
Type
Power Supply
Power Supply
Capacity
Electric
Consumption
Ice Production
per 24h
Dimensions
Refrigerant
Insulation Foam
Blowing Agent
Weight
Ambient Temp
Water Supply
Temp
Water Supply
Pressure
Voltage Range
KM-470AJ/
KM-470AJ-S
Air-cooled,
crescent cube ice
1 phase 220-240V
50Hz/
1 phase 220-230V
60Hz
3.45 kVA (15.0A) /
3.51 kVA (15.2A)
1850W / 1910W
(AT:32°C,WT:21°C)
495kg / 505kg
(AT:10°C,WT:10°C)
762mm(W) x
695mm(D) x
825mm(H)
R404A
1.40kg (GWP:3920,
CO2: 5.488t)
Cyclopentane
Net:122kg
(Gross:136kg)
7 - 38°C
7 - 32°C
0.07 - 0.78MPa
(0.7 - 7.8bar)
198 - 254V
KM-470AWJ/
KM-470AWJ-S
Water-cooled,
crescent cube ice
1 phase 220-240V
50Hz/
1 phase 220-230V
60Hz
3.64 kVA (15.8A) /
3.51 kVA (15.3A)
1523W / 1634W
(AT:32°C,WT:21°C)
495kg / 500kg
(AT:10°C,WT:10°C)
762mm(W) x
695mm(D) x
825mm(H)
R404A
0.80kg (GWP:3920,
CO2: 3.136t)
Cyclopentane
Net:107kg
(Gross:121kg)
7 - 38°C
7 - 32°C
0.07 - 0.78MPa
(0.7 - 7.8bar)
198 - 254V
3
ENGLISH

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-470awjKm-470aj-sKm-470awj-s