Specifications; Electrical And Refrigerant Data - Hoshizaki KMH-2100SRJZ Instruction Manual

Stackable crescent cuber
Table of Contents

Advertisement

I. Specifications
A. Electrical and Refrigerant Data
The rating label and nameplate provide electrical and refrigerant data. The rating label
can be seen by removing the front panel. The nameplate is located on the rear panel. For
certification marks, see the nameplate.
We reserve the right to make changes in specifications and design without prior notice.
1. KMH-2100S_J(Z)/3
Single Phase
Model Number
KMH-2100SRJZ
AC Supply Voltage
208-230/60/1
Compressor
208-230V 10.9RLA 73LRA
Pump
120V 1.2FLA 60W
Fan
120V 3A MAX (Fans in URC)
Other
115V 0.3A
Maximum Fuse Size 30 AMPS
Max. HACR Breaker
30 AMPS
(USA Only)
Max. Circuit Breaker
30 AMPS
(Canada Only)
Minimum Circuit
30 AMPS
Ampacity
Design Pressure
HI-467PSI LO-230PSI
Refrigerant
404A
Total Refrigerant Charge with
Hoshizaki Remote Condenser
Unit URC-22FZ: 16 LB. 1.5 OZ.
Model Number
KMH-2100SWJ3
AC Supply Voltage
208-230/60/3
Compressor
208-230V 8.4RLA 66LRA 208-230V 7.9RLA 66LRA
Pump
120V 1.2FLA 60W
Fan
--- --- ---
Other
115V 0.3A
Maximum Fuse Size 20 AMPS
Max. HACR Breaker
20 AMPS
(USA Only)
Max. Circuit Breaker
20 AMPS
(Canada Only)
Minimum Circuit
20 AMPS
Ampacity
Design Pressure
HI-427PSI LO-230PSI
Refrigerant
404A
3 LB. 1.4 OZ.
Three Phase
KMH-2100SRJZ3
208-230/60/3
120V 1.2FLA 60W
120V 3A MAX (Fans in URC)
115V 0.3A
20 AMPS
20 AMPS
20 AMPS
20 AMPS
HI-467PSI LO-230PSI
404A
Total Refrigerant Charge with
Hoshizaki Remote Condenser
Unit URC-22FZ: 16 LB. 1.5 OZ.
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kmh-2100swj3Kmh-2100srjz3

Table of Contents