I. Specifications
A. Electrical and Refrigerant Data
The rating label and nameplate provide electrical and refrigerant data. The rating label
can be seen by removing the front panel. The nameplate is located on the rear panel. For
certification marks, see the nameplate.
We reserve the right to make changes in specifications and design without prior notice.

1. F-450MAJ(-C)

Single Phase
Model Number
AC Supply Voltage
Compressor
Gear Motor
Fan Motor
Other
Maximum Fuse Size 15 AMPS
Max. HACR Breaker
(USA Only)
Max. Circuit Breaker
(Canada Only)
Minimum Circuit
Ampacity
Design Pressure
Refrigerant

2. F-801M_J(-C)

Model Number
AC Supply Voltage
Compressor
Gear Motor
Fan Motor
Other
Maximum Fuse Size 15 AMPS
Max. HACR Breaker
(USA Only)
Max. Circuit Breaker
(Canada Only)
Minimum Circuit
Ampacity
Design Pressure
Refrigerant
F-450MAJ(-C)
115/60/1
115V 8.4RLA 50LRA
115V 2.4FLA 1/4HP
115V 1FLA 50W
115V
0.03A
15 AMPS
15 AMPS
15 AMPS
HI-427PSI LO-230PSI
404A 15.2 OZ.
Single Phase
F-801MAJ(-C)
115/60/1
115V 7.5RLA 54.5LRA
115V 3.0FLA 200W
115V 1.0FLA 1/15HP
115V 0.03A
15 AMPS
15 AMPS
15 AMPS
HI - 467PSI LO - 250PSI
404A 1 LB. 12 OZ.
F-801MWJ(-C)
115/60/1
115V 7.5RLA 54.5LRA
115V 3.0FLA 200W
– – –
115V 0.03A
15 AMPS
15 AMPS
15 AMPS
15 AMPS
HI - 467PSI LO - 250PSI
404A 10.7 OZ.