Line Set Installation - Hoshizaki KM-470AJ Instruction Manual

Modular crescent cuber
Hide thumbs Also See for KM-470AJ:
Table of Contents

Advertisement

ENGLISH

5. Line Set Installation

Precharged factory line sets, available as optional equipment from Hoshizaki are
recommended. For details, see "II.G.5.a) Factory Line Set Installation." Field fabricated line
sets are allowed. For details, see "II.G.5.b) Field Fabricated Line Set Installation."
a) Factory Line Set Installation
1) Route the factory line set from the remote condenser unit to the icemaker. Leave a
service loop behind the icemaker to allow the icemaker to be pulled out for service. See
Fig. 11. Factory fabricated line sets are precharged and do not need to be evacuated. If
the line set is too long or too short, see "II.G.5.a)(1) Factory Line Set Modification."
• Ensure that there are no traps and no kinks in the line set. The service loop is not
considered an oil trap.
• Do not coil extra line set.
2) Connect the refrigerant lines to the appropriate male fittings on the remote condenser
unit first and then at the icemaker. Make a proper connection as follows:
a. Remove the protective covers from the male fitting and female coupling.
b. Apply Polyol Ester (POE) refrigerant oil or Parker Super O Lube to the entire male
fitting, including O-ring, diaphragm, and threads before making the connection.
See Fig. 12. NOTICE! Do not use thread sealant on the fittings. Use POE
refrigerant oil or Parker Super O Lube only. Couplings are one-time use only.
c. Make sure the male fitting and female coupling are properly aligned, then start the
connection by hand to ensure that it is not cross threaded.
d. Place a backup wrench on the back of the female coupling, then tighten the
connection with a wrench until it is tight. At this point, the nut has covered most of the
threads on the male fitting. NOTICE! Failure to use a backup wrench may result in
damage to the line set and possible refrigerant leaks.
e. Mark a reference line on the female coupling and the remote condenser unit or
icemaker panel. Using a backup wrench on the back of the female coupling, tighten
the six-sided nut of the female coupling an additional 1/6 turn. See Fig. 13.
NOTICE! Confirm connection is free of leaks.
3) If you lengthened the line set as outlined in "II.G.5.a)(1) Factory Line Set Modification"
and it exceeds 20 m, see "II.G.4. Line Set Exceeding 20 m " for proper charging of the
appliance.