Siemens MD720-3 Manual page 15

Sending and receiving of text messages via serial cps/cms and gprs/gsm modem
Hide thumbs Also See for MD720-3:
Table of Contents

Advertisement

Table of contents
Function chart of an error status
The following figure shows an example of an error that may occur during
initialization as, for example, the PIN could not be transferred to the modem.
Figure 2-5
INIT
ERROR
STATUS
BUSY
2.5
STATUS output of the function blocks
For error diagnostics, the function blocks of the SMS_MD720-3_Library_V13 library
have a STATUS output. By reading the STATUS output of the function block, you
are provided with information on logical errors and error messages that may occur
during the transfer between the communications processor and the GSM modem.
Table 2-4
Status
16#8101
16#8102
16#8103
16#8104
16#8105
Sending and Receiving SMS Messages with MD720-3
Entry ID: 25545680,
V1.0,
approx.
3 sec
Meaning
The watchdog timer has expired during
modem initialization because:
1.
The short message service center
number is incorrect
2.
Communication between the
controller and the modem is
interrupted during initialization
Incorrect PIN
The modem could not be set to text
mode.
The SMS indicators could not be
transferred.
The storage duration of the SMS
message could not be transferred to the
modem.
12/2013
Change PIN
16#8102
approx.
20 sec
Support / Remarks
Check and change the short
message service center
number
Check the cable between the
controller and the modem
Restart initialization
Check and change the PIN
Restart initialization
Restart initialization
Restart initialization
Restart initialization
Active through user
Reaction block
Reaction block
Reaction block