56
Monitoring
Temperature, advanced cooling modules, power supplies, disk drives,
and I/O option modules are all monitored by the Environmental
Services block built into the ESM and TSM.

Disk Drives

Support for 3.5" SCSI disk drives of 1.0" height
Support for 10K RPM and higher (15K, 30W/slot peak)

Power supply

AC power supply input
Input voltage: 85 - 264 VAC
Current rating: 10 - 5 Amps
Input frequency: 47 - 63 Hz
Maximum peak output power: 853 Watts
Maximum average output power: 673 Watts
Temperature
Operating Temperature: 5
Storage Temperature: -40
Maximum rate of temperature change: 20
Humidity
Relative operating humidity: 10% to 80%, non-condensing
Relative storage humidity: 10% to 95%, non-condensing
Altitude
Operating Altitude: -61m to 3,047m (-200 to 10,000 feet)
Storage Altitude: -61m to 12,187m (-200 to 40,000 feet)
Appendix A: Technical specifications
o
o
C to +40
C
o
o
C to +70
C
o
C per hour