56
Monitoring
Temperature, advanced cooling modules, power supplies, disk drives,
and I/O option modules are all monitored by the Environmental
Services block built into the ESM and TSM.
Disk Drives
•
Support for 3.5" SCSI disk drives of 1.0" height
•
Support for 10K RPM and higher (15K, 30W/slot peak)
Power supply
•
AC power supply input
•
Input voltage: 85 - 264 VAC
•
Current rating: 10 - 5 Amps
•
Input frequency: 47 - 63 Hz
•
Maximum peak output power: 853 Watts
•
Maximum average output power: 673 Watts
Temperature
•
Operating Temperature: 5
•
Storage Temperature: -40
•
Maximum rate of temperature change: 20
Humidity
•
Relative operating humidity: 10% to 80%, non-condensing
•
Relative storage humidity: 10% to 95%, non-condensing
Altitude
•
Operating Altitude: -61m to 3,047m (-200 to 10,000 feet)
•
Storage Altitude: -61m to 12,187m (-200 to 40,000 feet)
Appendix A: Technical specifications
o
o
C to +40
C
o
o
C to +70
C
o
C per hour