3.2.2 Introduction of Status Bar

Status Description
Measurement
Status
Control Mode
Screenshot Status
Trigger Mode
Remote
Compensation
USB Status
System Time
Alarm
Trigger Ready
Start-Up Delay
Short-Circuit
Pause Operation

3.2.3 Running Indicator

UTL8500 series electronic load comes with running indicator on the ON button. In on-load
mode, the indicator will light up, indicating that the load is in a loaded status. Pressing the
ON button again can stop loading and the indicator will go out.

4. Measurement Setting

This chapter gives a detailed description of the main functions of the electronic load so that
you can have a deeper understanding on the operation of the electronic load. It mainly
contains the following contents:
Constant State Test Modes (CC/CV/CR/CP)
More Modes (Dynamic, List, Dual, OCP/OPP, etc.)
Parameter Input and Loading Measurement
Trigger Method
Sense
Screenshot
Display Status
Description of Function
Status (Mode)
Current Measurement Status or Work Mode
Local/Remote
Current Operating Mode: Local/Remote
Waiting/OK/Fail
Saving the Picture/Saved Successful/Fail
Manual/External
Current Trigger Mode: Manual/External
Sense Displays on the Screen: Remote
Sense
Compensation Has Been Turned on
USB Storage Device Has Been Connected
0000.00.00
Current System Time: Year/Month/Date /Hour/
00:00
Minute
Audio Alarm Is ON
Wait for Trigger, the Icon will Disappear after
Trig
Triggering
Wait for Start-Up Delay, the Icon will Disappear
Delay
when Reaching the Delay Time, and then Start
up
Short
In Short-Circuit Test Mode
Pause
In Pause Status