Massachusetts Requirements; Cold Climate Insulation; Manufactured Home Requirements - Superior Fireplaces DRT6300 Series Installation And Operation Instructions Manual

Power-vent direct-vent gas fireplaces
Table of Contents

Advertisement

INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340TYN AND DRT6345TYN) • INSTALLATION INSTRUCTIONS
NOTE: Flame appearance will diminish 4%
per one thousand feet of altitude.
Burner Orifice Size
Elevation 0 - 4500 ft (0 - 1370 m)
Model
Natural Gas
0.125" (1/8") *
40"
H7924 •
0.136" (#29) *
45"
H8141 •
* Standard size installed at factory
Table 4
• Part /Cat. Number
In Canada - CAN/CGA-2.17-M91 (R2009) (high
altitude):
THE CONVERSION SHALL BE CARRIED OUT
BY A MANUFACTURER'S AUTHORIZED REP-
RESENTATIVE, IN ACCORDANCE WITH THE
REQUIREMENTS OF THE MANUFACTURER,
PROVINCIAL OR TERRITORIAL AUTHORITIES
HAVING JURISDICTION AND IN ACCORDANCE
WITH THE REQUIREMENTS OF THE CAN/CGA-
B149.1 OR CAN/CGA-B149.2 INSTALLATION
f i r e - p a r t s . c o m
CODES.
COMMONWEALTH OF MASSACHUSETTS
REQUIREMENTS
These appliances are approved for installation in
the US state of Massachusetts if the following
additional requirements are met:
• Install this appliance in accordance with
Propane Gas
Massachusetts Rules and Regulations 248
0.082" (#45)
C.M.R. Sections 4.00 through 8.00.
J8002 •
• Installation and repair must be done by a
0.086" (#44)
plumber or gas fitter licensed in the Com-
H2287 •
monwealth of Massachusetts.
• The flexible gas line connector used shall
not exceed 36 inches (92 centimeters) in
length.
• The individual manual shut-off must be a
T-handle type valve.
Massachusetts Horizontal Vent Requirements
In the Commonwealth of Massachusetts, hori-
zontal terminations installed less than seven
(7) feet above the finished grade must comply
with the following additional requirements:
• A hard wired carbon monoxide detector
with an alarm and battery back-up must be
installed on the floor level where the gas
fireplace is installed. The carbon monoxide
detector must comply with NFPA 720, be
ANSI/UL 2034 listed and be ISA certified..
• A metal or plastic identification plate must
be permanently mounted to the exterior of
the building at a minimum height of eight (8)
feet above grade and be directly in line with
the horizontal termination. The sign must
read, in print size no less than one-half (1/2)
inch in size, GAS VENT DIRECTLY BELOW.
KEEP CLEAR OF ALL OBSTRUCTIONS.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

COLD CLIMATE INSULATION

For cold climate installations, seal all cracks
around your appliance with noncombustible
material and wherever cold air could enter
the room. It is especially important to insulate
outside chase cavity between studs and under
floor on which appliance rests, if floor is above
ground level. Gas line holes and other open-
ings should be caulked or stuffed with unfaced
fiberglass insulation.
If the fireplace is being installed on a cement
slab in cold climates, a sheet of plywood or
other raised platform can be placed underneath
to prevent cold transfer to the fireplace and
into the room. It also helps to sheetrock inside
surfaces and tape for maximum air tightness
and caulk firestops.
MANUFACTURED HOME
REQUIREMENTS
This appliance may be installed in an aftermar-
ket permanently located, manufactured home
and must be installed in accordance with the
manufacturer's instructions.
Cet appareil peut être installé cómme
du matéri-el d'origine dans une maison
préfabriquée (É.U. seulement) ou mobile
et doit être installé selon les instructions
du fabricant.
This appliance is only for use with the type of
gas indicated on the rating plate. This appliance
is not convertible for use with other gases.
Cet appareil doit être utilisé uniquement
avec le type de gaz indiqué sur la plaque
signalétique. Cet appareil ne peut être
converti à d'autres gaz.
CAUTION: Ensure that the cross mem-
bers are not cut or weakened during
installation. The structural integrity of
the manufactured home floor, wall, and
ceiling/roof must be maintained.
CAUTION: This appliance must be
grounded to the chassis of the manu-
factured home in accordance with local
codes or in the absence of local codes,
with the National Electrical Code ANSI /
NFPA 70 - latest edition.