• An appliance operated with the air shutter
opened too far, may have flames that appear
blue and transparent. These weak, blue and
transparent flames are termed anemic.
The following chart is provided to aid in correctly
adjusting the air shutter.
Air Shutter Adjustment Guidelines
Amount of
Flame
Primary Air
Color
If air shutter is
Flame will
closed too far
be orange
If air shutter is
Flame will
open too far
be blue
Burner Air Shutter Adjustment Procedure
WARNING
• Air shutter adjustment should
only be performed by a quali-
f i r e - p a r t s . c o m
fied professional service tech-
nician.
• Ensure that the front glass
door assembly is in place and
sealed After adjustment.
CAUTION
Soot will be produced if the
air shutter is closed too much.
Any damage due to carboning
resulting from improperly setting
the air shutter is not covered
under the warranty.
To adjust the flame, move the adjustment air
shutter (located on the lower venturi) back or
forward to increase or reduce the air shutter
opening, respectively. Position the air shutter to
the factory setting as shown in Figure 40. Allow
the burner to operate for at least 15 minutes.
Observe the flame continuously. If it appears
weak or sooty as previously described, adjust
the air shutter until the flame appearance is
as desired.
When satisfied that the appliance operates
properly, finish the installation. Leave the
ON/REMOTE/OFF wall switch in the REMOTE
position and turn the remote switch OFF.
Use the remote to adjust the flame height
as desired.
Main Burner Factory Air Shutter
Opening Setting - Inches (millimeter)
Model
Air Shutter
Adjustment
Air shutter
gap should be
increased
Air shutter
gap should be
decreased
Figure 40 - Air Shutter Adjustment
Figure 41 - Burner Flame Appearance
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Nat.Gas
40"
1/8" (3.18 mm)
45"
1/8" (3.18 mm)
Air Shutter
Opening
Venturi
Orifice
Gas
Valve
Burner
Venturi