MAINTENANCE SCHEDULE

Turn OFF gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
Annually (Before the onset of the Burning Season)
MAINTENANCE TASK
Inspect/Clean Burner, Logs
and Controls
Check Flame Patterns and Flame
Height
Inspect/Clean Pilot and Burner
Check Vent System
f i r e - p a r t s . c o m
Appliance Checkout
Replace Glowing Embers
Periodically (After the Burning Season)
MAINTENANCE TASK
Clean Firebox Interior
Check Flame Patterns and Flame
Height
Check Vent System
Clean Front Glass Enclosure Panel
50
PERFORMED BY
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Homeowner/Qualified Service
Technician
PERFORMED BY
Homeowner
Homeowner
Homeowner
Homeowner
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
PROCEDURE
Inspect valve and ensure it is properly operating. Check piping for
leaks. Vacuum the control compartment, fireplace logs and burner
area.
Refer to Figure 60 on Page 43 and verify the flame pattern and height
displayed by the appliance conforms to the picture. Flames must not
impinge on the logs. Ensure flames are steady (not lifting or floating).
Refer to Figure 61 on Page 43. Remove any surface build-up on pilot
and burner assembly. Wipe the pilot nozzles, igniter/flame rod and
hood. Ensure the pilot flame engulfs the flame sensor as shown.
Inspect the vent system at the top and at the base (within the firebox)
for signs of blockage or obstruction. Look for any signs of dislocation
or deterioration of the vent components.
NOTE: Excessive condensation can cause corrosion of caps, pipe,
and fittings (excessive condensation can be caused by long lateral
runs, too many elbows and/or exterior portions of the system being
exposed to cold weather). Also, inspect wall straps or plumbers's
tape to ensure it is secure and in place.
Perform the appropriate appliance checkout procedure detailed in this
manual.
Remove old ember materials (rockwool) and vacuum the ember
placement area. Place new embers per instructions on Page 41.
PROCEDURE
Carefully remove logs, rockwool and volcanic stone. Vacuum out
interior of the firebox. Clean firebox walls and log grate. Replace logs,
glowing embers (rockwool) and volcanic stone as detailed in this
manual.
Refer to Figure 60 on Page 43 and verify the flame pattern and height
displayed by the appliance conforms to the picture. Flames must not
impinge on the logs.
Inspect the vent system at the top and at the base (within the firebox)
for signs of blockage or obstruction. Look for any signs of dislocation
of the vent components (reconnect or replace as necessary).
Clean as necessary following the directions provided in this manual.
NOTE: DO NOT TOUCH OR ATTEMPT TO CLEAN GLASS WHILE HOT.