Install The Finishing Materials; Attach The Safety-In-Operation Warnings; Installing Batteries For Backup And Wall Switch - Superior Fireplaces DRT4000 Series Installation And Operation Instructions Manual

Direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
DRT4000 Series Direct-Vent Gas Fireplaces
Reinstall the Included Barrier
21.
Reinstall any barrier removed before operating the fireplace. The barrier is designed to
reduce the risk of burns from hot glass. Do not operate the fireplace without the barrier
installed.
NOTE: All models must have a barrier installed prior to operation.
1. Open the control compartment door (Page 51).
2. Hold the barrier in front of the glass door and slide it up into the slots above the glass door and under the hood.
3. Slide the barrier bottom down into the slots below the glass door, securing it in place.

Install the Finishing Materials

22.
1. Complete finished interior wall.
NOTE: To install the fireplace facing flush with the finished wall, position framework to accommodate the thickness
of the finished wall.
Figure 40 - Combustible Wall Framing
Finished Wall
NOTE: See Cold Climate Insulation on Page 10 and Vent Termination Clearances on Page 12.
Attach the Safety-in-Operation Warning Labels
23.
1. Attach the furnished safety instruction labels at all fireplace operation and control points (Page 45).
NOTE: The installer MUST ensure these warnings are properly attached during installation. The warning labels are a
critical means of informing consumers of safe operation practices.

Installing Batteries for Backup and Wall Switch

24.
1. Locate the battery backup and place four (4) AA batteries in the backup battery holder (Page 38).
2. Locate the wall switch and secure four (4) AA batteries in the wall switch battery holder (Page 38).
NOTE: Replace batteries as a part of standard maintenance (Pages 52 and 61) and as needed when troubleshooting
(Page 71).
44
This Area
Must Remain
Clear of
Combustible
Materials
1" Min.
Combustible
(26 mm)
Materials
Stand Off
Must Be Bent
To Vertical
Position
Standoff
Provides
Space From
Combustible
Top Of
Materials
Appliance
4" Clearance
Minimum
Hood
WARNING
3"
(77 mm)
Installation
900697-01 11/2017