11. Removal Procedure

11.1 Removal Procedure of Indoor Unit

18/24K
1. Remove filter as s y
Open the front panel. Push the left and right
filters to make them break away from the
groove on the front case. Then remove the left
and right filters one by one.
Screw off the 2 screws that are locking the
display board. Separate the display board from
the front panel.
Installation and Maintenance
Warning: Be sure to wait for a minimum
of 20 minutes after turning off all power
supplies and discharge the refrigerant
completely before removal.
Front panel
Left filter
Groove
S
Front
case
Right filter
85