5)
Press as to select [MODE].
6)
Press qw to switch the item.
f The items will switch each time you press the button.
[OFF]
[MASTER]
[SLAVE]
f When anything other than [OFF] is selected, the diagnostic result is displayed in [LINK STATUS], indicating
if all the projectors including the projectors targeted for synchronization are correctly connected, and if
[MODE] is correctly set.
[LINKED]
[NO LINK]
7)
Press as to select [SHUTTER SYNC].
8)
Press qw to switch the item.
f The items will switch each time you press the button.
[OFF]
[ON]
Note
f The [MULTI PROJECTOR SYNC] setting item is common with the following menu item.
g The [PROJECTOR SETUP] menu → [MULTI PROJECTOR SYNC]
For details on contrast synchronization function, refer to the [PROJECTOR SETUP] menu → [MULTI PROJECTOR SYNC] (x page 181).
f The shutter synchronization function will operate when all of the following conditions are fulfilled.
g All the projectors to be linked are connected in a loop with the daisy chain connection. (Maximum 64 projectors)
g [MODE] on only one projector that is linked is set to [MASTER], and [MODE] on all other projectors are set to [SLAVE].
g [SHUTTER SYNC] on the projectors to perform the shutter synchronization is set to [ON].
f It is possible to set [SHUTTER SYNC] to [OFF] for the projectors that are linked but not to synchronize.
f The shutter operation by the shutter synchronization function will follow the setting of the [DISPLAY OPTION] menu → [SHUTTER
SETTING] on the projector that [MODE] is set to [MASTER].
f The operation of the mechanical shutter is not included in the shutter synchronization function.
f When the input signal to each linked projector is not synchronized, the timing of the shutter operation between the projectors may shift up to
1 frame while using the shutter synchronization function.
f The shutter function of the projector with [MODE] set to [SLAVE] can be operated individually. The shutter operation at this time will follow
the setting of the [DISPLAY OPTION] menu → [SHUTTER SETTING] set in that projector.

[FREEZE]

Pause the projected image temporarily regardless of the playback of the external device.
1)
Press as to select [FREEZE].
2)
Press the <ENTER> button.
f Press the <MENU> button to release.
Note
f [FREEZE] is displayed on the screen when video is paused.
f When an image from one input terminal is displayed on multiple screens while in the four-screen display mode, the appearance may vary for
each image being paused. Set the [MULTI DISPLAY] menu → [MULTI DISPLAY MODE] to anything other than [OFF] when using the four-
screen display mode.
154 - ENGLISH
Chapter 4 Settings — [DISPLAY OPTION] menu
Select this item when the contrast synchronization function and the shutter synchronization function
are not used.
Select this item when the contrast synchronization function or the shutter synchronization function is
used.
Set this item only on one of the linked projectors that becomes the synchronization source of the
shutter operation.
Select this item when the contrast synchronization function or the shutter synchronization function is
used.
Set this item in all the linked projectors excluding the projector set as the [MASTER].
All the projectors are correctly connected, and correctly set. They are in the condition that the contrast
synchronization function or the shutter synchronization function can be used.
The projectors are not correctly connected, or not correctly set. Check the cable connection status
and the projector setting for each projector that is linked.
Select this item when the shutter synchronization function is not used.
Select this item when the shutter synchronization function is used.