RCM Series Rack Mounting

The RCM416 / RCM816 can be mounted in a 19" 1U rack and the RCM464V
can be mounted in a 2U rack. The mounting brackets screw into either the front
or the back of the unit so that it can attach to the front or the back of the rack.

Rack Mounting - Front

To mount the unit at the front of the rack, do the following:
1. Remove the screws at the front of the unit.
Phillips head
hex M3 x 6
2. Use the M3 x 8 Phillips head hex screws supplied with the rack mount kit
to screw the rack mounting brackets into the front of the unit.
3. Position the device in the front of the rack and align the holes in the
mounting brackets with the holes in the rack.