Service And Adjustments; Adjust Access Panel Cam Latch; Electrical Service - Gravely Pro-Stance 48 Operator's Manual

Hide thumbs Also See for Pro-Stance 48:
Table of Contents

Advertisement

SERVICE AND
ADJUSTMENTS
WARNING: AVOID INJURY.
Read and understand entire
Safety section before
proceeding.
ADJUST ACCESS PANEL CAM
LATCH
See Figure 26.
Access panel should be held tightly against
control panel by the cam latch to tightly seal
the area and not rattle during operation.
To adjust:
1. Loosen lock nut retaining catch.
2. Move eccentric catch to desired position.
3. Tighten lock nut.
4. Close panel to ensure latch catches the
eccentric and that desired seal is
achieved.
5. Readjust if necessary.
2
1. Lock Nut
2. Eccentric Catch
3. Cam Latch
Figure 26
3
1

ELECTRICAL SERVICE

The fuse/relay panel is located behind the
rear access panel, below the control panel.
See Figure 27.
Replace Fuse
NOTICE: To avoid damaging the circuit,
replace fuses with fuses of the same
amperage rating. Determine the cause of
electrical failure and repair before replacing
failed electrical components.
1. Remove defective fuse.
2. Determine cause of fuse failure and
repair condition.
3. Install new fuse.
Replace Relay
NOTICE: Relays are interchangeable. Use
only quality replacement parts. See Service
Parts on page 21.
1. Remove defective relay.
2. Determine cause of relay failure and
repair condition.
3. Install new relay.
Fuse Block Diagram
START/RUN
RELAY
STARTER
SOLENOID
RELAY
EN - 26
10A
CONTROLS
FUSE
PTO
RELAY
20A
CHARGING
FUSE
10A
PTO
OPERATOR
FUSE
PRESENCE
TIME DELAY
RELAY
07700114
Harness Main Fuse Location
Figure 27
15A
AUXILIARY
FUSE
10A
TIME DELAY
FUSE
15A
ACCESSORY
FUSE

Hide quick links: