Specifications - Omron E8F2 Instruction Manual

Pressure sensor
Hide thumbs Also See for E8F2:
Table of Contents

Advertisement

E8F2

Specifications

Ratings/Characteristics
Item
Power supply voltage
Current consumption
Pressure type
Rated pressure range
Pressure setting range
Withstand pressure
Applicable fluid
Operating mode
Repeat accuracy
(ON/OFF output)
Linearity
Response time
(ON/OFF output)
Linear output
ON/OFF output
Load current
Output applied voltage
Residual voltage
Display (see note 2)
Display accuracy
Circuit protection
Ambient temperature
Ambient humidity
Temperature influence
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Pressure port
Connection method
Cable
Weight (incl. packing material)
Material
Pressure port
Case
Accessory
Note: 1. The current consumption is approximately 43 mA in energy-saving mode.
2. Display Example of Digital Indicator
Model
kPa
Applied
pressure
E8F2-A01C
100
1 0 0 0
E8F2-B10C
1,000
1 0 0 0
E8F2-AN0C
–101
2
E8F2-A01C
12 to 24 VDC ± 10% with a ripple (p-p) of 10% max.
70 mA max. (see note 1)
Gauge pressure
0 to 100 kPa
0 to 100 kPa
400 kPa
Non-corrosive gas and non-flammable gas
Hysteresis mode, window mode, and auto-teaching mode
±1% FS max.
±1% FS max.
5 ms max.
1 to 5 V± 5% FS with an output impedance of 1 kΩ and a permissible resistive load of 500 kΩ
min.
NPN open collector (NO/NC)
30 mA max.
30 VDC max.
1 V max. with a load current of 30 mA
3.5-digit red LED
Green LED bar indicator
The orange LED is lit for two independent outputs with output transistor turned ON
Green unit indicator
±3% FS ± 1 digit max.
Reverse polarity connection, load short-circuiting
Operating: 0°C to 55°C
Storage:
–10°C to 60°C (with no icing)
Operating/Storage: 35% to 85% (with no condensation)
±3% FS max.
±1.5% FS max.
100 MΩ min. (at 500 VDC) between current-carry parts and case
1,000 VAC at 1 min
Destruction:
10 to 500 Hz, 1.0-mm double amplitude or 150 m/s
and Z directions
2
300 m/s
(30G) 3 times each in X, Y, and Z directions
IEC60529, IP50
R(PT) 1/8 taper screw and M5 female screw
Pre-wired (standard length: 2 m)
Approved by UL
Approx. 110 g
Aluminum die cast
Heat-resistive ABS
Mounting Bracket and instruction sheet
Setting unit
mmHg
Digital
Applied
Digital
display
pressure
display
.
Cannot be set
.
1 0 1 0
7 6 0 –1.01
–760
E8F2-B10C
0 to 1 MPa
0 to 1 MPa
1.5 MPa
kgf
Applied
Digital
pressure
display
.
1
1 0 0 0
.
10
1 0 0 0
.
1 0 1 0
E8F2
E8F2-AN0C
0 to –101 kPa
0 to –101 kPa
400 kPa
2
, 3 times each for 11 min in X, Y,

Advertisement

Table of Contents
loading