Advertisement

E8F2
Window Range Settings
1. Press the SET Key while wid is displayed to display the window width of OUT1 presently set.
2. Press the Up or Down Key to change the set value within a range between 0 and 30% FS of the reference value.
3. Press the SET Key to select the displayed set value and display the window width of OUT2 presently set.
4. Press the Up or Down Key to change the set value.
5. Press the SET Key to select the displayed set value and display wid again.
6. Press the Up and Down Keys simultaneously to display wid again without selecting the set value.
Note: No window width settings will be enabled in hysteresis mode.
Display Refresh Interval Settings
The following refresh intervals are selectable.
0.1: The average value is displayed at 0.1-s intervals.
0.5: The average value is displayed at 0.5-s intervals.
1.0: The average value is displayed at 1.0-s intervals.
or
Measurement Value Averaging Time Setting
The number of measurements can be set to 1, 8, 32, or 256.
or
1. Press the SET Key while aUe is displayed to display the set
value as the number of measurements for averaging
measured values.
2. Press the Up or Down Key to change the set value.
3. Press the SET Key to select the displayed set value and
display aUe again.
4. Press the Up and Down Keys simultaneously to display aUe
again without selecting the set value.
Note: If the DSP item is set to 0.5 and AVE item is set to 32, the
E8F2 will measure 32 times, the average value of which will
be treated as one block. The average block value for 0.5 s
will be displayed at 0.5-s intervals.
14
or
Press Up or Down Key
to change set value.
Press Up or Down Key to
change set value.
Press Up or Down Key to
change set value.
ON
OFF
1. Press the SET Key while dsp is displayed to display the
display refresh interval presently set.
2. Press the Up or Down Key to change the set value.
3. Press the SET Key to select the displayed set value and
display dsp again.
4. Press the Up and Down Keys simultaneously to display dsp
again without selecting the set value.
Note: Set the AVE to the number of measurements for obtaining
an average value.
E8F2
(0 to 30%)
Pressure
Reference value
value
(TEACH1)