BEA CONDOR ID Quick Manual page 3

Rfid gate sensor
Table of Contents

Advertisement

WIRING
12-24V
GREEN
GND
BROWN
COM
WHITE
NO
YELLOW
NC
GREY
COM
PINK
NO
VIOLET
NC
BLACK
DETECTION FIELD
START
1
Installation height: 2.5m
Field size: 7
Rejection mode: 1 (detection of pedestrians)
The IR-detection field is approx.15% smaller than the zone detected by the Spotfinder.
If rejection mode 2 (detection of pallets) is selected, the radar detection field is slightly smaller.
The angle of the radar field can be adapted by turning the adjustment screw.
If the adjustment screw has to be repositioned to the default position as shown above, it is mandatory to
start from the 12 o'clock position and turn counterclockwise to the 9 o'clock position.
POWER-
SUPPLY
START-
SIGNAL
NOT USED
STOP-
SIGNAL
NOT USED
STOP
m
0
1
m
1
2
3
-
By turning the screw clockwise, the detection depth decreases resp.
The detection field approaches the sensor.
+
By turning the screw counter clockwise, the detection depth
increases.
The Spotfinder is necessary to position the
detection field correctly.
The CONDOR ID should be positioned by using
the Spotfinder so that the START-line is at the
desired distance from the sensor.
Therefore the Spotfinder should be put on the
floor and turned towards the sensor. The
CONDOR ID should be adjusted until the
Spotfinder detects the first line of IR-spots.
1
0
Installation height: 3.2m
Field size: 8
Rejection mode: 1 (detection of pedestrians)
m
1
m
1
2
3
3/8