4.2.1.6

Displaying heading or speed information

This setting allows to check the heading information of selected sensor, the speed in-
formation of the Log or information about supply voltages.
Operation of push
after switching switch
8 into the upper posi-
*Designations of SEN1 to SEN4 depends on the respective CAN bus address.
Lowest address is SEN1
-- Switch 8 of the DIP--Switch into the upper position.
-- By operating the push button B22 (right side) the display shows the heading value
(the speed or supply voltage) of the selected sensor (see table above).
-- After this check, the switch 8 has to be set into lower position.
Edition: November 21, 2003
Distribution Unit
button B23
tion
1x
2x
3x
4x
5x
5x
138- -118
Display
Heading information
Sen1
Sen2
Sen3
Sen4
PLoG
P--11
11VDC supply vol-
tage of the I/O PCB
P--35
35VDC operating vol-
tage for the 1/6 Step
function of the I/O
PCB
25
DISTRIBUTION
UNIT
xxx.x°*
xxx.x°*
xxx.x°*
xxx.x°*
+/--Kts
3647.DOC010302