Page 1
Raytheon Marine GmbH High Seas Products Postfach 1166 D - - 24100 Kiel Germany Tel +49- -4 31- -30 19- -0 Fax +49- -4 31- -30 19- -291 Email ReceptionDE@raykiel.com www.raymarine.com DISTRIBUTION UNIT Type 138- -118 1 Description 2 Installation 3647.DOC010302 Edition:...
Page 2
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Copying of this document, and giving it to others and the use or Mitteilung ihres Inhaltes nicht gestattet, soweit nicht ausdrücklich communication of the contents thereof, are forbidden without express zugestanden. Zuwiderhandlungen verpflichten zu Schadenersatz. authority.
Distribution Unit DISTRIBUTION 138- -118 UNIT CONTENTS Page Declaration of Conformity ..........General .
Page 4
Distribution Unit 138- -118 3647.DOC010302 Edition: November 21, 2003...
Page 5
Distribution Unit DISTRIBUTION 138- -118 UNIT Edition: November 21, 2003 3647.DOC010302...
Page 6
Distribution Unit 138- -118 3647.DOC010302 Edition: November 21, 2003...
Page 7
Distribution Unit DISTRIBUTION 138- -118 UNIT Safety instructions Caution: Installation, maintenance and repair work must be carried out only by properly trained and qualified staff with a good knowledge of national equipment safety regulations. Edition: November 21, 2003 3647.DOC010302...
Page 8
Distribution Unit 138- -118 3647.DOC010302 Edition: November 21, 2003...
Distribution Unit DISTRIBUTION 138- -118 UNIT General The Distribution Unit 138--118 consists of an aluminium casting in which 2 printed circuit board are integrated. -- I/O--PCB -- Interface PCB. At the bottom of the casting there are 40 cable inlets for connecting repeaters, gyros and other heading receivers and sensors.
Distribution Unit 138- -118 CAN-Bus (CAN = Controller Area Network) Gyro compass The CAN bus is a Multi-Master-Bus allowing the connection of all devices and systems regardless of their task and function. This means that any number of devices can be connected. These de- vices must be designed for CAN bus technology.
Distribution Unit DISTRIBUTION 138- -118 UNIT Technical Data 1.2.1 Mechanical Data see Dimensional Drawing “Distribution Unit 138--118.HP005” Equiment cathegory: Protected from the weather 1.2.2 Electrical Data Supply Voltage: 15VDC..40VDC Max. Current: (2 Gyros and 8 Repeaters) Input: --Spd--Log --NMEA GPS --Log --CAN Bus --DV Bus (future purpose)
Distribution Unit 138- -118 Information about LED‘s, push buttons plugs and connectors of the integrated PCB‘s 4 5 6 7 8 9 10 11 12 13 14 Fig.2: Interface PCB (138--118.100) 3647.DOC010302 Edition: November 21, 2003...
Page 13
Distribution Unit DISTRIBUTION 138- -118 UNIT Designation at the Interface Remark Fig.2/1 Terminal Board L1 of the Connection of supply voltages Distribution Unit for the distribution unit itself and for connected gyros, operator unit and heading receivers. Fig.2/2 LED H1 +5VDC DC/DC--Converter for CAN--Bus and Course Bus Fig.2/3...
Page 14
Distribution Unit 138- -118 5 6 7 Fig.3:I/O PCB (138--118.101) 3647.DOC010302 Edition: November 21, 2003...
Page 15
Distribution Unit DISTRIBUTION 138- -118 UNIT Designation at the I/O PCB Remark Fig.3/1 Connector B1 Connection to the CAN Network Modul Interface PCB Fig.3/2 LED H30 35VDC Voltage (Step) Fig.3/3 Push Button B40 Processor Reset Fig.3/4 LED +5V5 +5VDC for RoT--Conversion Fig.3/5 LED +5V4 +5VDC galvanically seperated...
Page 16
Distribution Unit 138- -118 Designation at the I/O PCB Remark Fig.3/21 Plug B28 Output Channel 6 with 3 LED‘s blue = NMEA 2 green = NMEA 1 red = Course bus Fig.3/22 Plug B27 Output Channel 5 with 3 LED‘s blue = NMEA 2 green = NMEA 1 red = Course bus...
Page 17
Distribution Unit DISTRIBUTION 138- -118 UNIT Designation at the I/O PCB Remark Fig.3/47 Plug B22 with LED H13 Reserve Fig.3/48 Plug B19 with LED H10 Status--Signal with indication GYRO SELECTED Fig.3/49 Plug B16 with LED H7 Status--Signal with indication MONITORALARM GYRO/TMC Fig.3/50 Plug B13 with LED H4 Status--Signal with indication SENSORALARM G2...
Distribution Unit 138- -118 Installation of the Distribution Unit General remarks Caution When establishing cable connections ensure that the cables are disconnected from the power supply. It is essential to ensure that all cables are disconnected from the power supply, if necessary measure the voltage beforehand and/or disconnect the relevant distributor.
Page 19
Distribution Unit DISTRIBUTION 138- -118 UNIT -- Push the counterpart of the earthing insert as far as the end of the cable shield. -- Push the earthing insert cone below the shielding against the counterpart. Observe a shared evenly distribution of the shielding via the cone (see Fig. 3). Wall and DIN socket Cable Shielding...
Distribution Unit 138- -118 2.1.1 General information about establishing an earth connection In order to comply with the stringent EMC requirements, please abide by the information given below regarding cable connections. Use the cable types specified. Earth connections should be connected to the gyro compass and to the junction box. It is essential to ensure that these connections have a common reference to the ship’s earth.
Distribution Unit DISTRIBUTION 138- -118 UNIT Installation The distribution unit has to be mounted according to the dimensional drawing 138--118.HP005. The front cover should be removable. Please note the coment depending the internal protection at the dimensional drawing. 2.2.1 Installation of the options For installations of the options, as there are “Additional Output Box”...
Page 22
Distribution Unit 138- -118 The installation of the power supply (AC/DC--Converter) should only be per- formed by an experienced electrician. The supply voltage hast to be engineered as a low--security-- voltage acoording to SELV. Plastic cover Adhesive cable tie mounts Tie wrap Fig.8 Cable connections at the AC/DC--Converter...
Distribution Unit DISTRIBUTION 138- -118 UNIT Connections All connections to terminal boards and plugs have to be made according appended drawings. Please note manufacturer recommendations depening on the cable--diameters. 2.3.1 Connection of the Options For connection of the options, as there are “Additional Output Box” and “AC/DC--Con- verter”, see service manual of the Compass STD 22 Compact.
Distribution Unit 138- -118 Setting of Jumpers and DIP- -Swiches Setting of Jumpers Basicly 2 jumpers have to be set. These jumpers are the terminators (resisters which terminate the CAN--bus). Is a distribution Unit used as an so called “end--device” within a CAN--bus application, both jumpers have to be set.
Distribution Unit DISTRIBUTION 138- -118 UNIT Setting of DIP- -Switches Fig.10: DIP--Switches, display and push buttons to select operation modes 1 = DIP--Switch B20 with 8 single switches 2 = Push button B23 to select the modes within the respective DIP--Switch settings 3 = Diplay 4 = Push button B22 to set selected mode 4.2.1...
Distribution Unit 138- -118 4.2.1.1 Setting of CAN Bus address Each device within a CAN bus application has to be identified with an address. This address must not be twice within this application (bus--conflict)!! The CAN bus adress is already adjusted by the manufacturer. Below mentioned procedure to adjust the address is opnly necessary if a second Dis- tribution Unit should be connected.
Distribution Unit DISTRIBUTION 138- -118 UNIT 4.2.1.2 Adjustment of the 8 output channels Each of the 8 output channels can be set to 3 different interfaces. These interfaces are: Course bus, NMEA1 and NMEA2. With the formats NMEA1 and NMEA2 to different configurations can be adjusted, these configurations become active after selection (to the respective output channel).
Page 28
Distribution Unit 138- -118 Operation of push Display Interface button B23 after switching (B20) switches 1,2,and 3 Chn1 into the upper posi- tion HSEr Course bus (red LED) nME1 NMEA1 (green LED) nME2 NMEA2 (blue LED) Chn2 HSEr Course bus (red LED) nME1 NMEA1 (green LED) nME2...
Distribution Unit DISTRIBUTION 138- -118 UNIT 4.2.1.3 Adjustments of NMEA Formats Each NMEA--interface can be adjusted depending the data--format. Procedure for NMEA1: -- Switch 1 of the DIP--Switch into the upper position. Operation of push Display Interface button B23 after switching (B20) switch 1 into the up- per position nME1...
Page 30
Distribution Unit 138- -118 Procedure for NMEA2: -- Switch 2 of the DIP--Switch into the upper position. Operation of push Display Interface button B23 after switching (B20) switch 2 into the up- per position nME2 NMEA Channel2 nME1.0 NMEA 1.0sec nM0.1 NMEA 0.1sec EHdT...
Distribution Unit DISTRIBUTION 138- -118 UNIT 4.2.1.4 Scaling of RoT Output For the RoT--output an adjustment of the turn rate has to be performed. Procedure: -- Switch 3 of the DIP--Switch into the upper position. Operation of push Display Rate of Turn button B23 after switching (B20) switch 3 into the up-...
Distribution Unit 138- -118 4.2.1.5 Selection of magetic compass By this, it is adjusted, if the application is supported by a magnet compass or not. -- Switch 4 of the DIP--Switch (B23) into the upper position. -- The display shows MAGn. If this display--information blinks, then it is selected and the distribution unit is prepared to support a magnetic compass.
Distribution Unit DISTRIBUTION 138- -118 UNIT 4.2.1.6 Displaying heading or speed information This setting allows to check the heading information of selected sensor, the speed in- formation of the Log or information about supply voltages. Operation of push Display Heading information button B23 after switching switch 8 into the upper posi-...
Distribution Unit 138- -118 Switching OFF the Distribution Unit By switching OFF the supply voltage, the distribution unit is switched OFF. 3647.DOC010302 Edition: November 21, 2003...
Distribution Unit DISTRIBUTION 138- -118 UNIT Adjustments Adjustment of magnetic sonde This adjustment should be performed only be well trained stuff. Necessary tools and measuring instruments -- Screw driver to adjust potentiometer -- Voltmeter -- Iron tool to influence the magnetic sonde TP12 TP11 R155...
Page 36
Distribution Unit 138- -118 Adjustment after installation of the magnetic sonde (see Fig.11) The Distribution Unit is in operation. Magnetic sonde is installed and connected to the Distribution Unit. -- Switch the switches 6,7 and 8 of the DIP switch B20 into the upper position “OPEN”). -- Operate push button B22 until the display shows “MAGS”.
Distribution Unit DISTRIBUTION 138- -118 UNIT Maintenace and Repair The Distribution Unit is maintenace free. A repair only can be performed by exchanging the PCB’s. Fault Finding procedures are acually not available. Operation during a repair can only be performed when the CAN--bus is terminated.
Distribution Unit 138- -118 Functional description of DIP switch settings in the Service mode All data stated below should be selected and read out for servicing purposes only. In standard operation the following data has no significance. Seq. Indications Comments, Notes UnCo = (Uncorrected Compass) = heading without speed error correction value.
Page 39
Distribution Unit DISTRIBUTION 138- -118 UNIT Seq. Indications Comments, Notes GYr1 = Displays uncorrected heading (without SEC) for Gyro compass 1 DIP switch B20 OPEN 1 2 3 4 5 6 7 8 If there is no “Gyro 1” connected. Addr = Displays CAN--bus address for Gyro Compass 1 DIP switch B20 OPEN...
Page 40
Distribution Unit 138- -118 Seq. Indications Comments, Notes GYr2 = Displays uncorrected heading (without SEC) for Gyro compass 2 DIP switch B20 OPEN 1 2 3 4 5 6 7 8 If there is no “Gyro 2” connected. Addr = Displays CAN--bus address for Gyro Compass 2 DIP switch B20 OPEN 1 2 3 4 5 6 7 8...
Page 41
Distribution Unit DISTRIBUTION 138- -118 UNIT Seq. Indications Comments, Notes GYr3 = Displays uncorrected heading (without SEC) for Gyro compass 3 DIP switch B20 OPEN 1 2 3 4 5 6 7 8 If there is no “Gyro 3” connected. Addr = Displays CAN--bus address for Gyro Compass 3 DIP switch B20 OPEN...
Page 42
Distribution Unit 138- -118 Seq. Indications Comments, Notes MAGS = Displays heading of magnetic compass DIP switch B20 OPEN 1 2 3 4 5 6 7 8 No heading available or heading of magne- tic compass faulty No magnetic compass connected MAGC = Displays corrected heading or magnetic compass...
Page 43
Distribution Unit DISTRIBUTION 138- -118 UNIT Seq. Indications Comments, Notes MISS = Displays Variation value DIP switch B20 OPEN 1 2 3 4 5 6 7 8 dEvI = Displays deviation value Value out of an internal table, respective to the actual magnetic compass heading DIP switch B20 OPEN...
Page 44
Distribution Unit 138- -118 Seq. Indications Comments, Notes V--M = Displays this speed, which is manually set at the Operator Unit DIP switch B20 OPEN 1 2 3 4 5 6 7 8 Range: --90.0..90.0 SCi = Serial Interface, telegram traffic on serial interface DIP switch B20 OPEN 1 2 3 4 5 6 7 8...
Page 45
Distribution Unit DISTRIBUTION 138- -118 UNIT Seq. Indications Comments, Notes SrC.S = Source Speed Information Data about the source providing the speed value DIP switch B20 OPEN 1 2 3 4 5 6 7 8 Display options: PULS = Pulsl log = Speed over ground = Speed through water (vtG and vhW corresponds to...
Page 46
Distribution Unit 138- -118 Seq. Indications Comments, Notes vtG.S = Speed from GPS--telegram (speed over ground) DIP switch B20 OPEN 1 2 3 4 5 6 7 8 No, or faulty data from GPS (vTg--telegram) vtG.h = Course value from GPS telegram DIP switch B20 OPEN 1 2 3 4 5 6 7 8...
Page 47
Distribution Unit DISTRIBUTION 138- -118 UNIT Seq. Indications Comments, Notes vhw = Speed value in knots from NMEA telegram (speed through water) DIP switch B20 OPEN 1 2 3 4 5 6 7 8 No, or faulty serial speed data (vHw--telegram) SPd.A = Speed in knots (actual value) The speed for which the source has been selected, is displayed.
Page 48
Distribution Unit 138- -118 Seq. Indications Comments, Notes PoS = Position -- latitude in degrees DIP switch B20 OPEN 1 2 3 4 5 6 7 8 No latidude data available (GPS defective) ASPd = Alarm Speed DIP switch B20 OPEN 1 2 3 4 5 6 7 8 3 2 1 0...
Page 49
Distribution Unit DISTRIBUTION 138- -118 UNIT Seq. Indications Comments, Notes PoSn = Latitude value derives from automatic latitude input. Indicated in degrees DIP switch B20 OPEN 1 2 3 4 5 6 7 8 In case of a fault, the last actual latitude is displayed.
Page 50
Distribution Unit 138- -118 Seq. Indications Comments, Notes nAn1 = 1st table for NMEA--requests DIP switch B20 OPEN 1 2 3 4 5 6 7 8 L = telegram type GLL G = telegram type GGA t = telegram type VTG h = telegram type VHW 1st digit = number of L--types 2nd digit = number of G--types...
Page 51
Distribution Unit DISTRIBUTION 138- -118 UNIT Seq. Indications Comments, Notes nSGG = NMEA--telegram (strings of the GGA--telegram) DIP switch B20 OPEN 1 2 3 4 5 6 7 8 Number of ASCII--characters per telegram 0000 = no telegram The number of operations depends on the num- ber of characters.
Page 52
Distribution Unit 138- -118 Seq. Indications Comments, Notes nSGL = NMEA--telegram (String of the GLL--telegram) DIP switch B20 OPEN 1 2 3 4 5 6 7 8 Example Length of the telegram = 44 ASCII--charcters 3647.DOC010302 Edition: Feb. 14, 2004...
Page 53
Distribution Unit DISTRIBUTION 138- -118 UNIT Seq. Indications Comments, Notes nSGL = NMEA--telegram (Strings of the GLL--telegram) cont.2 DIP switch B20 OPEN 1 2 3 4 5 6 7 8 Checksum Edition: Feb. 14, 2004 3647.DOC010302...
Page 54
Distribution Unit 138- -118 Seq. Indications Comments, Notes nSGL = NMEA--telegram (Strings of the GLL--telegram) cont.2 DIP switch B20 OPEN 1 2 3 4 5 6 7 8 With the 1st operation of the contact switch B23, the number of ASCII--characters is displayed.
Page 55
Distribution Unit DISTRIBUTION 138- -118 UNIT Seq. Indications Comments, Notes nShw = NMEA--telegram (Strings of the VHW--telegram) DIP switch B20 OPEN 1 2 3 4 5 6 7 8 Number of ASCII--characters per telegram 0000 = no telegram The number of operations depends on the number of characters.
Page 56
Distribution Unit 138- -118 Seq. Indications Comments, Notes nSbw = NMEA--telegram (String of the VBW--telegram) DIP switch B20 OPEN 1 2 3 4 5 6 7 8 Number of ASCII--characters per telegram 0000 = no telegram The number of operations depends on the number of characters.
Page 57
Distribution Unit DISTRIBUTION 138- -118 UNIT Seq. Indications Comments, Notes Development only! SCI . = Serial Communicaion Interface NMEA Log/ GPS input) DIP switch B20 OPEN 1 2 3 4 5 6 7 8 The content of the two digits is during a datatransfer unrecognizeable.
Page 58
Distribution Unit 138- -118 Seq. Indications Comments, Notes AAdd = Alarm address of a defective Gyro compass DIP switch B20 OPEN 1 2 3 4 5 6 7 8 0000 ® kein fehlerhafter Gyro, sonst dessen Adresse dUin = Software version of the CAN--bus processor of the Interface PCB DIP switch B20 OPEN 1 2 3 4 5 6 7 8...
Page 59
Distribution Unit DISTRIBUTION 138- -118 UNIT Seq. Indications Comments, Notes dnbS =Software version of the DV--bus processor of the Interface PCB DIP switch B20 OPEN 1 2 3 4 5 6 7 8 Edition: Feb. 14, 2004 3647.DOC010302...
Page 60
Distribution Unit 138- -118 3647.DOC010302 Edition: November 21, 2003...