4.2
Setting of DIP- -Switches
Fig.10:
1 = DIP--Switch B20 with 8 single switches
2 = Push button B23 to select the modes within the respective DIP--Switch settings
3 = Diplay
4 = Push button B22 to set selected mode
4.2.1
General information in use of the DIP- -Switch and push buttons
The normal operation of the all DIP--Switches is the "DOWN"--position.
This means the repective switch is closed.
In the upper position the respective switch is open and by this, a mode can be selected
and adjusted.
After a switch is set into the upper position, a mode can be selected by the the push but-
ton on the left of the display (push button B23).
Before setting the selected mode the display--information does not blink.
After acknowledgement of selected mode with the push button on the right of the display
(push button B22) the display information is blinking -- this means selected mode is set.
After setting a mode all switches have to be set into the down--position (exception CAN--
bus adress).
Edition: November 21, 2003
Distribution Unit
2
1
DIP--Switches, display and push buttons to select operation modes
138- -118
4
3
17
DISTRIBUTION
UNIT
3647.DOC010302