4.2.3 HORIZONTAL AIR TERMINAL INSTALLATION

4.2.3 HORIZONTAL AIR TERMINAL INSTALLATION
EN
TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE
TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE
DO NOT ALLOW THE INNER FLEX PIPE TO BUNCH UP ON HORIZONTAL OR VERTICAL RUNS AND
DO NOT ALLOW THE INNER FLEX PIPE TO BUNCH UP ON HORIZONTAL OR VERTICAL RUNS AND
SPACERS ARE ATTACHED TO THE INNER FLEX AT PREDETERMINED INTERVALS TO MAINTAIN AN
SPACERS ARE ATTACHED TO THE INNER FLEX AT PREDETERMINED INTERVALS TO MAINTAIN AN
EVEN AIR GAP TO THE OUTER FLEX PIPE. THIS GAP IS REQUIRED FOR SAFE OPERATION. A
EVEN AIR GAP TO THE OUTER FLEX PIPE. THIS GAP IS REQUIRED FOR SAFE OPERATION. A
SPACER IS REQUIRED AT THE START, MIDDLE, AND END OF EACH ELBOW TO ENSURE THIS GAP
SPACER IS REQUIRED AT THE START, MIDDLE, AND END OF EACH ELBOW TO ENSURE THIS GAP
A.
Stretch the inner  ex pipe to the required length
taking into account the additional length needed for
the  nished wall surface. Apply a heavy bead of the
high temperature sealant W573-0007 Mill Pac (not
supplied) to the inner sleeve of the air terminal. Slip
the vent pipe a minimum of 2" (50.8mm) over the inner
sleeve of the air terminal and secure with 3 #8 screws.
B.
Using the outer rigid pipe, slide over the outer combustion air
sleeve of the air terminal and secure with 3 #8 screws. Seal
using high temperature sealant W573-0002 (not supplied).
C.
Insert the vent pipes through the  restop maintaining the required clearance to combustibles. Holding the air
terminal (lettering in an upright, readable position), secure to the exterior wall and make weather tight by sealing
with caulking (not supplied).
D.
From inside the house, using silicone, seal between the vent
pipe and the  restop. Then slide the black trim collar over the
vent pipe up to the  restop.
E.
If more vent pipe needs to be used to reach the appliance,
couple them together as illustrated. The vent system must
be supported approximately every 3 feet (0.9m) for both
vertical and horizontal runs. Use noncombustible strapping
to maintain the minimum clearance to combustibles.
The air terminal mounting plate may be recessed into the exterior wall or siding no greater than the depth of its
return fl ange.
W415-1427 / B / 08.01.18
!
!
RETURN FLANGE OF THE MOUNTING PLATE.
RETURN FLANGE OF THE MOUNTING PLATE.
ELBOWS. KEEP IT PULLED TIGHT.
ELBOWS. KEEP IT PULLED TIGHT.
IS MAINTAINED. THESE SPACERS MUST NOT BE REMOVED.
IS MAINTAINED. THESE SPACERS MUST NOT BE REMOVED.
WARNING
WARNING
#10x2"
SCREWS
CAULKING
HI-TEMP
SEALANT
OUTER
RIGID PIPE
7" (177.8mm) RIGID
PIPE
2" (50.8mm) OVERLAP
HIGH TEMP
SEALANT
#8 X 1/2"SELF DRILLING
SCREWS & WASHERS
INNER COUPLER
OUTER
RIGID PIPE
INNER
FLEX PIPE
W415-1427 / 12.23.14
21