Basic Maintenance Schedule - Generac Power Systems MLT4060MV Owner's Manual

Light tower
Table of Contents

Advertisement

Maintenance
Figure 4-1. Proper Mast Cable Routing
Verify safety pins for the mast lock rod and mast
lock bar are present and secured with a chain.
Verify the mast lock bar spring is not broken or
missing. Check the operation of the mast lock bar.
Verify the wheel lugs are present and properly
tightened. Refer to
Check coolant level daily. Normal operating level is
between the 'full' and 'add' markings on the
overflow jug. Refer to the engine operator's manual
for coolant recommendations and proper mixture.
AFTER
ENGINE
COMPLETELY COOL, coolant may be added
directly to the coolant overflow jug.

Basic Maintenance Schedule

Refer to the original equipment manufacturer's operating manual for a complete list of maintenance requirements.
Failure to comply with the procedures as described in the engine operator's manual will nullify the warranty, decrease
performance and cause equipment damage or premature failure. Maintenance records may be required to complete a
warranty request. Use the schedule in the following table as a guide for regular maintenance intervals. For additional or
replacement copies of the engine operator's manual, contact a GMASD.
ITEM
Check oil level
Check coolant level
Check fuel level
Check tire pressure
Check all electrical connections
Inspect radiator fins for debris, clean as required
Inspect light tower winch for proper operation
Fuel tank - drain water
Check air cleaner
Belt and belt tension - inspect and adjust
Replace fuel filter
Drain and clean fuel tank
Check glow plugs
Lubricate leveling jacks
Replace engine oil and oil filter
Bolts and nuts on the engine - retighten
Replace heated fuel filter (if equipped)
Inspect engine starting battery
*
Perform after the initial 50 hours of operation, then on the regularly scheduled interval indicated in the schedule above.
**
Certain conditions may require the fuel tank to be drained and cleaned more often. When operating in extremely
dusty conditions, clean the fuel tank as often as necessary.
22
Towing
Safety.
IS
STOPPED
Basic Maintenance Guide (Mitsubishi Engine)
Check oil level daily. Refer to the engine operator's
manual for the appropriate oil specification. Verify the
oil is correct for special operating conditions such as a
change in season or climate.
DO NOT start the unit if the engine oil level is below
the add mark on the dipstick.
Normal operating level is in the cross-hatch pattern
between the full and add markings on the dipstick.
Add oil only if the oil level is below the add mark on
the bottom of the cross-hatch pattern on the dipstick.
DO NOT OVERFILL the crankcase.
Check the fuel level.
AND
If the unit is connected to a remote start or transfer
switch, verify the remote switch is off and tagged.
50
250
DAILY
Hr
Hr
400
500
750
Hr
Hr
Hr
**
Owner's Manual for Mobile Light Tower
1,000
Hr
*
*

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mlt4060kvMlt4080kv

Table of Contents