General Information
Control Panel - MLT4080KV
L
TURN
MAIN
BREAKER
OFF
K
BREAKER
J
(A) Main Circuit Breaker
This 240V (40A) breaker will disconnect power to the
lights and auxiliary outlets. It will also disable the starting
circuit if engine starting is attempted when the main
breaker is on.
(B) Light Switch (4 Locations)
One circuit breaker is supplied for each light.
(C) Ballast Indicator Light (4 Locations)
Indicates power from the ballast to each light.
(D) 240V Breaker
This 240V (30A) circuit breaker is supplied for the 240V
twist-lock receptacle.
(E) Engine Starting Switch
Keyed switch operates glow plugs, starts and stops
engine.
(F) Glow Plug Indicator (if equipped)
Indicates operation of the engine glow plugs (Mitsubishi
engines only).
12
A
MAIN
BREAKER
240V
ON
ON
120V
120V
BREAKER
120V
120V
Figure 2-5. Control Panel
B
C
BALLAST INDICATOR LIGHTS
I
I
I
ON
ON
ON
O
O
O
MAST LIGHT SWITCHES
GLOW
PLUG
240V
BREAKER
I
ON
ON
O
240V
NEUTRAL BONDED TO FRAME
I
(G) Engine Hour Meter
Keeps track of engine hours for service.
(H) DC Circuit Breaker
Circuit breaker (10A) for the engine electrical system.
(I) 240V Twist-Lock Outlet
This 240V (30A) outlet supplies power for accessories
connected to the generator when the engine is running
and the main circuit breaker is switched ON (I).
(J) 120V GFCI Outlet (2 Locations)
This unit 120V (20A) GFCI outlet supplies power for
accessories connected to the generator when the engine
is running and the main circuit breaker is switched ON (I).
(K) 120V Breaker (2 Locations)
This 120V (20A) circuit breaker is supplied for the 120V
GFCI duplex outlets.
(L) Circuit Breaker Indicator Light
This light indicates that the main circuit breaker must be
opened (switched off) before starting the engine.
D
I
ON
O
OFF
GLOW PLUG
RUN
INDICATOR
START
DC
BREAKER
Owner's Manual for Mobile Light Tower