Chapter 5 Specifications; Specifications - Iwatsu SS-293S Instruction Manual

Rogowski coil current probe
Table of Contents

Advertisement

Chapter 5 Specifications

Chapter 5 Specifications

5.1 Specifications

Basic specifications
Sensitivity [mV/A]
Peak current [kA]
Peak di/dt [kA/μs]
Absolute maximum di/dt
Frequency bandwidth
Low frequency cutoff [Hz]
Noise [mV rms]
Sensitivity accuracy
Output
Connector
Linearity
Zero point adjustment range
Sensor part
Coil length
Wire rod diameter at coil part
Maximum rating voltage
between ground
Sensor cable length
Operating temperature range
General specification
Dimensions
Weight
Power supply
Battery longevity
24
SS-293S/L
S:60/L:32
Peak [kA/μs]
RMS [kA/μs]
f
to 20 MHz [−3 dB] SS-29xS
L
f
to 10 MHz [−3 dB] SS-29xL
L
±2%
At the center of the coil loop with sensor part temperature
of −10C to +70C
*: Add an error of ±250 ppm/C when the temperature is
−10C or less or +70C or more.
Maximum voltage range: ±6 V (load ≥ 100 kΩ)
BNC
±0.05% of full scale
±300 mV or more
SS-29xS: 300 mm ±10 mm, SS-29xL: 700 mm ±10 mm
8.5 mm (max.)
10 kV peak (resisting voltage guarantee range:
Refer to Section 4.3.2)
3.0 m ±100 mm
−40 to 125C (including sensor cable)
Approx. 80 (W) × 165 (H) × 35 (D) mm
(excluding protrusions)
SS-29xS: Approx. 0.48 kg, SS-29xL: Approx. 0.50 kg
Four AA dry batteries
Approx. 30 hours (when alkaline batteries are
Note 2
used)
SS-294S/L
5
2
1.2
3
80
80
80
3.0
3.0
f
1
0.8
3.5
2.0
Note 1
SS-295S/L
SS-296S/L
1
0.5
6
80
80
3.0
3.0
: Low frequency cutoff
L
0.6
0.4
1.4
1.2
12
80
80

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ss-293lSs-294sSs-294lSs-295sSs-295lSs-296s ... Show all

Table of Contents