Troubleshooting; Troubleshooting Schedule - Husqvarna LB 548 i Workshop Manual

Table of Contents

Advertisement

8.1 Troubleshooting schedule

Problem
Possible cause
There is no battery in the
battery box.
The battery is defective.
The safety key is not fully in-
stalled in the safety lock.
The relay is defective.
The prod-
Wire fault.
uct does
not start.
The control panel is defec-
tive.
The primary control unit is
defective.
The prod-
The micro switch in the han-
uct does
dle is defective.
not start,
the warn-
Wire fault.
ing indica-
tor does
not come
The primary control unit is
on.
defective.

34 - Troubleshooting

8 Troubleshooting
Step
Troubleshooting
Make sure that the battery is installed cor-
1
rectly.
Push the button on the battery and do a
1
check of the battery error condition.
Make sure that the safety key is put in cor-
1
rectly in the safety lock.
Make sure that there is a click sound when
1
the ON/OFF button is pushed.
Do a check of the connection to the handle. Connect the wires
1
Do a check of the wires, refer to the wiring
2
diagram.
Do a visual inspection.
1
No troubleshooting is possible.
1
Examine the micro switch. Make sure that
1
there is a click sound when the motor
brake handle is pressed down.
Do a check of the wires, refer to the wiring
1
diagram.
No troubleshooting is possible.
1
To do
Install a battery.
Replace the bat-
tery.
Push the safety key
in the safety lock.
Replace the pri-
mary control unit.
correctly or replace
them if they are de-
fective.
Replace defective
wires.
Replace the control
panel if it is defec-
tive.
Replace the control
unit if it is defective.
Replace the micro
switch if it is defec-
tive.
Replace defective
wires.
Replace the control
unit if it is defective.
1410 - 001 -