SE500 MIDI Remote Control Command
1. Physical layer
1.5
Follow the MIDI SPEC. 1.0
1.6
Communication rate: 31250 BPS
1.7
Data format: 8 bits serial, LSB first, 1 start bit, 1 stop bit, none parity
2. Data link layer
2.1 Control messages = MIDI Channel voice messages
* Received only if Note Mode is ON
* The input of each channel is selected.
* Ignored if a non-selectable note message is received.
2.2 Control messages
* Note –on
Status
----------------------------------------------------------------------------
9nH
Symbol
----------------------------------------------------------------------------------------------------------------------------
n:
kk:
vv:
3. SE500 control command correspond to note number as follows
Note
Note No.
;
;
C4
48
C#4
49
D4
50
D#4
51
E4
52
F4
53
F#4
54
G4
55
G#4
56
A4
57
A#4
58
B4
59
C5
60
C#5
61
D5
62
D#5
63
E5
64
VER: 1.00a
Release date: 2005/06/03
nd
2
byte
kkH
Meaning
MIDI channel
Note number
= SE500 control command
Velocity value,etc.
Only in the case of Note-on Velocity
SE500 command
;
fade key
wipe key
wipe key
wipe key
wipe key
wipe key
wipe key
wipe key
wipe key
wipe key
wipe key
wipe key
SUB A key
QUAD key
SUB B key
SPLIT key
SUB C key
rd
3
byte
vvH
50
Range
0H-FH(ch.1--ch.16)
00H-7FH(0--127)
00H-7FH(0--127)
01H-7FH(1--127)

Hide quick links: