Genie GS-1330m Operator's Manual page 48

Table of Contents

Advertisement

Operator's Manual
Operating Instructions
Operational indicator codes
If the platform controls LED or ground controls
LCD diagnostic readout displays an operational
indicator code such as LL, the fault condition must
repaired or removed before resuming machine
operation. Push in and pull out the red Emergency
Stop button to reset the system.
LED Readout
LCD Readout
Operational Indicator Codes
Code
Condition
LL
Off-Level
OL
Platform Overloaded
CH
Chassis Mode Operation
PHS
Pothole Guard Stuck
ND
No Drive (option)
BR
Manual Brake Release
For further information, please consult the
appropriate Genie Service Manual. A code and a
description of a code can also be viewed at the
ground controls LCD display.
46
Platform Overload
If the platform controls LED diagnostic readout
displays a flashing OL and the ground controls
LCD diagnostic readout displays OL: Platform
Overloaded, the platform is overloaded and no
functions will operate. An alarm will sound.
1
Push in the red Emergency Stop button to the
off position.
2
Remove weight from the platform.
3
Pull out the red Emergency Stop button to the
on position.
When the platform is being raised or lowered, a
self-check function will be performed near
maximum height. The machine may stop and an
alarm may sound. If the machine is not
overloaded, normal operation will resume.
Overload Recovery
If the ground controls LCD diagnostic readout
displays Overload Recovery, the auxiliary lowering
system has been used while the platform was
overloaded. For information on how to reset the
message, please consult the appropriate Genie
Service Manual.
GS
-1330m
First Edition • Second Printing
LED Readout
LCD Readout
Part No. 1290846GT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Genie gs-1330mGenie gs30md-101Genie gs30md-3168

Table of Contents