Removal of Fan Rotor

10.Removal of Fan Rotor
Procedure
Step
1. Remove the right side
plate.
1
Remove the 2 screws
of the right side plate.
2
Release the fan motor
lead wires from the
hooks and remove the
right side plate.
Remove the 2 screws
3
of the fan motor fixing
plate.
28
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Preparation
Remove the indoor heat
Right side plate
exchanger according to the
"Removal of Indoor Heat
Exchanger."
(R4406)
(R4407)
(R4408)
Fan motor
fixing plate
(R4409)
Si041048
Points
Removal Procedure