Fan Motor

4. Fan Motor
Warning
Step
1
Cut the 2 clamps.
2
Remove the 2 bottom
screws.
3
Remove the 2 top
screws.
4
Remove the fan motor.
12
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Top screw
Bottom screw
Fan motor
Points
(R9630)
Be sure to remove the
bottom screws first. If the top
screws are removed first, the
fan motor may tilt down or
fall and cause injury.
(R24012)
When reassembling, make
sure that the wire harness is
facing downward.
Harness
(R6443)
Si001272EC
(R6444)
Removal Procedure