Removal Of Front Panel - Daikin FT25GV1G6 Service Manual

Removal procedure. 2.5/3.5/4.0 kw class. 9000/12000 btu/h class.
Hide thumbs Also See for FT25GV1G6:
Table of Contents

Advertisement

Removal of Front Panel

2. Removal of Front Panel
Procedure
Step
1. Remove the front panel.
1
Open the panel over
the position where it
stops.
2
Slide the left rotary
shaft to the right and
release it.
3
Slide the right rotary
shaft to the left and
release it.
4
Remove the front panel.
4
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Front panel
Rotary shaft
(R4312)
(R4313)
Rotary shaft
(R4315)
When reassembling the
front panel, fit the right and
left rotary shafts one by one
into the grooves and fully
push them into position.
(R17126)
Si041048
Points
Removal Procedure

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents