5.10.3 Electrical Diagram; 5.10.4 Ionisation Current - Riello 40 FS8 Installation, Use And Maintenance Instructions

Forced draught gas burners one-stage operation
Table of Contents

Advertisement

5.10.3 Electrical diagram

Key (Fig. 16)
C
Motor capacitor
CN1
Ionisation probe connector
E
Ignition electrode
h1
Hour counter (230V - 0.1A max.)
MV
Fan motor
PA
Air pressure switch
PG
Min. gas pressure switch
RS
Remote reset connection
SB
Lockout light (230V - 0.5A max.)
SM
One-stage damper conn.
SO
Ionisation probe
TB
Burner earth
TL
Limit thermostat
TS
Safety thermostat
T6A
Fuse
V1
Adjustment valve
VS
Safety valve
XP6
6 pin plug/socket
XP7
7 pin/plug socket
Testing
 Check the shut down of the burner by opening the thermo-
stats.
 Check that the burner is blocked while working by opening
the connector (CN1) inserted in the probe red wire and
located outside the control box.

5.10.4 Ionisation current

The minimum current necessary for the control box operation is
5 µA. The burner normally supplies a higher current value, so that
no check is needed.
Anyway, if you want to measure the ionisation current, you need
to open the connector (CN1)(Fig. 16) on the red wire and insert a
microammeter as shown in Fig. 17.