Cleaning and care
Checking the filters in the
wash cabinet
The filter combination in the base of the
wash cabinet retains coarse soil from
the suds solution, preventing it from
accessing the circulation system and
re-entering the cabinet through the
spray arms.
The dishwasher must not be
used without all the filters in place.
Collection of coarse soil may cause the
filters to clog. The level of soiling and
time it takes before the filters need
cleaning will vary depending on use.
The message
Check filters
the display after every 50 programme
cycles (factory default setting).
You can turn off the Check filters
reminder or set the interval for this
message to appear between 30 to 60
programme cycles (see "Settings
menu, Check filter").
 Check the filter combination.
 Clean it if necessary.
 Confirm the message with the middle
button.
The last programme selected will
appear briefly in the display and the
appropriate indicator light will come on.
After a short while, the estimated
running time for the programme will be
displayed.
50
will appear in

Cleaning the filters

 Switch the dishwasher off.
 Turn the handle anti-clockwise to
release the filter combination .
 Take the filter combination out of the
dishwasher . Remove any coarse
particles and rinse the filter well
under running water. If necessary,
use a soft washing-up brush to
remove soiling.
Make sure that when cleaning
the filters, no coarse soil falls into the
circulation system.
This could cause a blockage.