Heatilator NDV3630I-B Installation Manual
Hide thumbs Also See for NDV3630I-B:
Table of Contents

Advertisement

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
Models:
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certifi ed kit is used.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16
Installation Manual
Installation and Appliance Setup
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heatilator NDV3630I-B

  • Page 1 In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fi tter. See Table of Contents for location of additional Commonwealth of Massachusetts requirements. Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 2: Table Of Contents

    C. Accessories ........67  = Contains updated information. Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 3: Installation Standard Work Checklist

    _____________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date) = Contains updated information. 2382-982 11/15 Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 4: Product Specifi C And Important Safety Information

    Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order. Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 5: Non-Combustible Materials Specifi Cation

    • A 110-120 VAC circuit for this product must be pro- tected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 6: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 7: Getting Started

    Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 8: Framing And Clearances

    1003 6-1/2 165 mm 6-1/2 165 mm 34-1/2 34-1/2 8-5/8 11-5/8 4-3/8 5-7/8 11-5/8 11-5/8 19-1/8 19-1/8 2-3/8 2-3/8 Figure 3.1 Appliance Dimensions - NDV3630I-B/NDV3630IL-B, NDV3933I-B/NDV3933IL-B Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 9 23-1/2 39-1/2 1003 39-1/2 1003 6-1/2 6-1/2 34-1/2 34-1/2 14-5/8 20-5/8 7-3/8 10-3/8 11-5/8 11-5/8 19-1/8 19-1/8 2-3/8 2-3/8 Figure 3.2 Appliance Dimensions - NDV4236I-B/NDV4236IL-B, NDV4842I-B/NDV4842IL-B Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 10 1-7/8 6-3/4 31-7/8 DEMI-3933-B 32-7/8 20-3/8 35-7/8 1-7/8 6-3/4 31-7/8 DEMI-4236-B 38-7/8 20-3/8 41-7/8 1-7/8 6-3/4 31-7/8 DEMI-4842-B 1064 Figure 3.3 Decorative Front Dimensions - DEMI-B Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 11 1-7/8 6-3/4 31-7/8 TRES-3933-B 32-7/8 19-7/8 35-7/8 1-7/8 6-3/4 31-7/8 TRES-4236-B 38-7/8 19-7/8 41-7/8 1-7/8 6-3/4 31-7/8 TRES-4842-B 1064 Figure 3.4 Decorative Front Dimensions - TRES-B Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 12 32-7/8 1-5/8 6-3/4 29-5/8 SIM-3933 34-3/8 35-7/8 1-5/8 6-3/4 29-5/8 SIM-4236 40-3/8 41-7/8 1-5/8 6-3/4 29-5/8 SIM-4842 1026 1064 Figure 3.5 Decorative Front Dimensions - SIMON-B Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 13: Clearances To Combustibles

    1353 37-5/8 19-5/8 43-3/8 53-1/4 10-5/8 NDV4236I-B NDV4236IL-B 1067 1102 1194 1353 41-7/8 19-5/8 53-1/4 12-3/4 NDV4842I-B NDV4842IL-B 1219 1064 1194 1353 Figure 3.6 Appliance Locations Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 14 * Adjust framing dimensions for interior sheathing (such as sheetrock) C** Add 11-1/2 inches for rear vented elbow vented directly off the rear of the Figure 3.7 Clearances to Combustibles appliance. Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 15: Constructing The Appliance Chase

    (or an equivalent method may be making contact with fi replace or chimney. used) to achieve maximum air tightness. • Failure to maintain airspace may cause overheating and a fi re. Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 16: Termination Location And Vent Information

    Over 20/12 to 21/12 ..........8.0 * H minimum may vary depending on regional snowfall. Refer to local codes. Figure 4.1 Minimum Height From Roof to Lowest Discharge Opening Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 17: Chimney Diagram

    • Vinyl protection kits are suggested for use with vinyl siding. Figure 4.3 Minimum Clearances for Termination Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 18: Approved Pipe

    WARNING! Risk of Fire or Asphyxiation. This appli- ance requires a separate vent. DO NOT vent to a pipe serving a separate solid fuel burning appliance. Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 19: Use Of Elbows

    8-1/2 DVP24 DVP36 25-1/2 DVP48 1219 DVP6A 3 to 6 76 to 152 2-1/8-4-1/4 54-108 DVP12A 3 to 12 76 to 305 2-1/8-8-1/2 54-216 Figure 4.4 Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 20: Measuring Standards

    • Horizontal pipe installed level with no rise. MEASURE TO SHADED SURFACE (OUTSIDE MOUNTING SURFACE) Figure 4.6 Measure to Outside Mounting Surface Figure 4.7. Measure to Top of Last Section of Pipe Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 21: Vent Diagrams

    1/4 inch downward slant to allow any moisture in cap to be released. See Figure 4.8. 1/4 in. max. (6 mm) Figure 4.8 Water Infi ltration Prevention Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 22 60 ft (18.29 m) max. 12 ft (3.66 m) min. 60 ft (18.29 m) max. 2 ft. SLP DVP-SLP24 Adapter DVP-2SL  Figure 4.10 DVP-SLP24 Adapter Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 23 * You may install the elbow directly on top of the appliance (DVP only). NOTE: A minimum venting scenario consists of a 90 degree elbow off the top of the appliance with a DVP-TRAP2 horizontal termination cap. Figure 4.11 Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 24 7.62 m 22 ft. 6.7 m 25 ft. 7.62 m 22 ft. 6.7 m Maximum = 25 ft. (7.62 m) Installed Vertically Installed Horizontally Figure 4.12 Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 25 Top Vent - Horizontal Termination (continued) Three Elbows min. max. max. 12 in. 305 mm 25 ft. 7.62 m 19 ft. 5.79 m Elbows Installed Vertically Figure 4.13 Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 26 The top vent fl ue baffl e will be turned to install inside for 31-60 ft. vertical runs of vent. See Figure 4.17. Figure 4.17 31-60 Ft. Vertical Run Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 27 Maximum horizontal run ( is 100% of TOTAL vertical, but cannot exceed 26 ft (7.92 m). 12 ft (3.66 m) min. 60 ft (18.29 m) max. Figure 4.18 Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 28 ) is 100% of vertical, TOTAL but cannot exceed 23 ft (7.01 m). Elbows Installed Vertically 12 ft (3.66 m) min. 60 ft (18.29 m) max. Figure 4.19 Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 29 WARNING! Risk of Fire! This vent confi guration is not allowed with NDV4842I-B/NDV4842IL-B Note: To achieve optimum fl ame appearance, the vent confi gurations shown in Figure 4.11 and Figure 4.22 are recommended. Figure 4.21 Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 30 5 ft. 1.5 m 8 ft. 2.4 m 15 ft. 4.6 m 6 ft. 8 ft. 2.4 m 18 ft. 5.5 m INSTALLED HORIZONTALLY Figure 4.23 Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 31 60 ft (18.29 m) max. 6 ft (1.83 m) max. Maximum horizontal run (H )= 100% of Total vertical, but cannot exceed 26 ft (7.92 m) Figure 4.25 Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 32 Total 0 min. 6 ft (1.83 m) max. Maximum horizontal run is 100% of Total = vertical, but cannot exceed 26 ft (7.92 m). Figure 4.26 Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 33: Vent Clearances And Framing

    Top: 2-1/2 in. (64 mm) Bottom: 1/2 in. (13 mm) Sides: 1 in. (25 mm) Figure 5.1 Horizontal Venting Clearances To Combustible Materials Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 34: Wall Penetration Framing/Firestops

    If your local inspector requires the wall shield fi restop on both sides, then both wall shield fi restops must have a heat shield attached to them. Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 35: Ceiling Firestop/Floor Penetration Framing

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 5.4 Installing the Attic Shield Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 36: Appliance Preparation

    Attach the fi rst vent section. It will snap into place. Figure 6.3 • Cut the metal retaining band and fold the sides out. Proceed to Section 6.B. Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 37: Rear Vent

    Attach the fi rst vent section (it will snap into place). Slide the insulation gasket onto the vent section, up against the appliance and over the tabs. Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 38: Securing And Leveling The Appliance

    • Optional: Secure the appliance to the fl oor by inserting two screws through the pilot holes at the bottom of the appliance. Nailing Tabs (both sides) Figure 6.12 Proper Positioning and Securing of an Appliance Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 39: Venting And Chimneys

    Use screws no longer than 1/2 INCORRECT in. (13 mm). If predrilling screw holes, DO NOT penetrate Figure 7.4 Seams inner pipe. Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 40: Assemble Slip Sections

    • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Figure 7.5 Adding Venting Components Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 41: Secure The Vent Sections

    Figure 7.10 Rotate Seams for Disassembly connection point to appliance. 120º Figure 7.11 Align and Disassemble Vent Sections Figure 7.8 Securing Vertical Pipe Sections 120º Figure 7.9 Securing Horizontal Pipe Sections Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 42: Vertical Termination Requirements

    • Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 7.13. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 43: Horizontal Termination Requirements

    Figure 7.15 Figure 7.15 Important Notice: Heat shields may not be fi eld constructed. Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 44 SLP-TRAP2 can adjust 4 in. (5 1/4 to 9 1/4)) DVP-HPC1 can adjust 2 1/8 in. (4 1/4 to 6 3/8) DVP-HPC2 can adjust 4 1/8 in. (6 3/8 to 10 1/2) Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 45: Shrouds

    Min. Opening Width Min. Top Dims. 16 x 16 Min. Opening Height 406 x 406 Figure 7.17 Open Top Shroud Dimensions Figure 7.19 Roofed Style Shroud Dimensions Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 46: Electrical Information

    Verify proper operation after servicing. WARNING! Risk of Shock! Replace damaged wire with type 105º C rated wire. Wire must have high temperature insulation. Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 47: Wiring Requirements

    * GRN wire only used Pack with optional wall switch Control WSK-MLT-HTL Junction Wall Switch Adapter GRN* Valve Figure 8.2 Intellifi re Pilot Ignition (IPI) Wiring Diagram Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 48 Figure 8.3 Junction Box Wired to Wall Switch or BC10 (1/4 in. male) as shown. Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 49: Gas Information

    4500 feet (1370 m). • If substituting for these components, please consult local codes for compliance. Check with your local gas utility to determine proper orifi ce size. Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 50: Air Shutter Setting

    Maximum vent run consists of “H Maximum” on Figure 4.20. Note: All vent runs may need to be evaluated for ideal shutter settings. Shutter distances may vary due to vent run, fuel quality, and elevation. Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 51: Finishing

    0 in. 0 in. 0 in. High Temperature Sealant (300° F/149° C min.) Top and Side Seal Joint Figure 10.1 Non-combustible Facing Diagram Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 52: Mantel And Wall Projections

    3-1/2 in. (89 mm) min. from fireplace opening to perpendicular wall Figure 10.3 Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening) Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 53: Appliance Setup

    WARNING! Risk of Fire! Close the ball valve before in- stalling the splatter guard to prevent accidental lighting. Remove the splatter guard before lighting the appliance. Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 54: Install The Log Assembly

    Log #4 on the fl at spot on Log #1. Figure 3 shows locations of fl at spots. Figure 4 shows Log #4 installed. Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 55 See Figure 6. Slide Log #5 toward the right until it contacts the log pin as shown in Figure 6. Figure 7. Log Set Installed 2382-935 Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 56: Place The Mineral Wool

    ROCK (IF DESIRED) ROCK (IF DESIRED) FRONT BURNER PORT HOLES MINERAL WOOL LAVA ROCK AND VERMICULITE Figure 11.3 Placement of Mineral Wool, Lava Rock and Vermiculite Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 57: Reference Materials

    6 in. (152 mm) 14 IN. (356 MM) 12 IN. (305 MM) DVP-WS (Wall Shield Firestop) DVP-RDS ROOF DECK INSULATION SHIELD Figure 12.1 DVP Vent Components Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 58 117 mm Length DVP-TRAP 5-3/8 in. 9-3/8 in. Trap2 Horizontal Termination Cap 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 DVP-HPC1 DVP-HPC2 Figure 12.2 DVP Vent Components Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 59 9-1/2 in. (352 mm) (241 mm) 26 in. 660 mm 14 in. (356 mm) DVP-HSM-B DRC-RADIUS Extended Heat Shield Cap Shield Figure 12.3 DVP Vent Components Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 60 (222 mm) 7-3/4 to 10-3/8 in. (197 to 264 mm) 1-5/8 in. DVP-FBHT (41 mm) FireBrickTermination Cap DVP-HPC High Performance Cap Figure 12.4 DVP Vent Components Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 61 13-5/8 IN. 16-11/16 IN. 16-11/16 IN. (346 mm) 424 mm (424 mm) 12-1/2 IN. SLP-LPC (318 mm) SLP Low Profi le Cap Figure 12.5 Vent Components Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 62 100 FT PV Wire Harness PVI-WH100 separately. Use if the PVLP-SLP is installed in a high traffi c area. PVLP-HS PVLP-BEK Heat Shield Brick Kit Figure 12.6 PVLP-SLP Vent Components Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 63 1-1/2 in. 12 in. 5-1/2 in. 220 mm 38 mm 305 mm 146 mm SLP-WS SLP-FS Wall Shield Firestop Ceiling Firestop Figure 12.7 SLP Series Vent Components Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 64 (381 mm) 12-5/8 IN. 10-5/8 IN. (321 mm) (270 mm) SLP-RDS ROOF DECK INSULATION SHIELD SLP-HRC-SS Not approved for NDV4842 Figure 12.8 SLP Series Vent Components Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 65 3/8 in. (10 mm) 1 in. (25 mm) 7-3/4 to 10-3/8 in. (197 to 264 mm) DVP-FBHT Horizontal Termination Cap Figure 12.9 SLP Series Vent Components Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 66: Optional Components

    20 in. [508 mm] 17 in. [432 mm] 9-3/8 in. [238 mm] TCG375 Terra Cotta Cap See your Heatilator dealer for a complete listing of optional components. Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...
  • Page 67: Accessories

    Please contact your Heatilator dealer with any questions or concerns. For the location of your nearest Heatilator dealer, please visit www.heatilator.com. Printed in U.S.A. - Copyright 2016 Heatilator • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4842I-B Installation Manual • 2382-980 Rev. G • 4/16...