5

Framing and Clearances

A. Selecting Appliance Location
When selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat-
ed out of traffic and away from furniture and draperies.
NOTICE: Illustrations reflect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
E
1 IN.
A
Inches
Millimeters
Figure 5.1 Appliance Locations
A
B
C
TOP VENT
ONE 90
ELBOW
0
A
B
53-1/32
48
1347
1219
Heatilator • RAVE4013I-D • 2328-900 Rev. F • 9/17
It is important to follow the framing and finishing
instructions step by step to ensure proper placement of
fireplace in the surrounding framing/finishing materials.
Unlike many traditional, single sided Heatilator fireplaces,
the RAVE4013I-D is recessed into surround framing. The left
and right nailing tabs were designed to ensure the fireplace is
recessed to the correct location within the framing materials.
Refer to Section 13 for detailed instructions on finishing.
D*
ALCOVE
INSTALLATION
TOP VENT
ONE 90° ELBOW
B
C
D
75
See Section D.
Figure 5.5 & 5.6
1905
F
E
F
19-9/32
17-3/4
490
451
17