188 • Crestron SIMPL Windows

NOTICE (CMCVT112)

Could not create Signal Table file
C:\ANYDEALER\SIMPL\MYJOB\A12345.SIG
The .SIG file could not be opened for write. Generally this happens if another
application currently has the file open for write or there is no disk space left.

NOTICE (CMCVT113)

No data defined for S-1 Serial I/O str1, skipping
A signal name was typed on the input to a Serial I/O symbol or a Serial Driver
symbol, but no data was typed in for the symbol to trigger. The compiler will not
convert this signal or data field, so it skips over it.

NOTICE (CMCVT114)

CNIR-8 Slot 1 Port A str1 is greater than 254 characters, truncating to 254.
The total length of a function + delimiter on a 1 way serial driver is 254 characters.
If the total length exceeds 254 characters, the function is truncated to 254 characters.

NOTICE (CMCVT115)

Slot 1 Port A str1 is greater than 255 characters, truncating to 255.
S-1 Serial I/O str1 is greater than 255 characters, truncating to 255.
The total length of a function + delimiter on a 2 way serial driver or Serial I/O
symbol is 255 characters. If the total length exceeds 255 characters, the function is
truncated to 255 characters.

WARNING (CMCVT116)

Unable to open IR file C:\ANYDEALER\USERDB\MYFILE.IR on Slot-1
CNIR-6 Port A.
This error message may be issued if:
An IR Driver is missing from the Crestron Database. This usually happens if you
have an older version of the Crestron database than the program with which it was
created. When the program is opened through SIMPL Windows, it will tell you if the
Crestron database version is older than the program with which it was created.
An IR Driver is missing from the User Database. Verify that all the drivers that are
required are in the User database, and resort the user database.

NOTICE (CMCVT117)

RF Receiver, RF/IR ID 01 is illegal (RF/IR Transmitter ID's must be 10 or
greater).
Some Transmitters must be set to ID 10 or greater to function properly on a Cresnet
system. If one of those transmitters is in use and it's ID is set to less than 10, this
warning is issued.