142 • Crestron SIMPL Windows
Ethernet devices that are addressed by the control system may have their IP
addresses set either in the SIMPL Windows program or through the ViewPort with a
PC. Just as each Cresnet device is assigned a Cresnet ID, e.g. 03 through FE, to be
used when programming, an Ethernet device is assigned an IP ID which also may
range from 03 through FE. Ultimately, each IP ID is converted into an actual IP
address through an IP Table that exists inside the CNX control system. This will be
discussed in more detail below.
To add Ethernet devices to your program, in the SIMPL Windows' Configuration
Manager, drag an Ethernet-connected device, e.g. a CEN-IO or a Virtual Touchpanel
symbol, into the program. Drop it on the CNXENET card or the "Ethernet Units"
arrow underneath the "Cresnet Units" arrow. (Pull the window divider down further
if you don't see it in the System View window.)
Double click on the CEN-IO icon
box. Select the IP Net Address tab and assign an IP ID and a corresponding IP
address. For example, assign IP ID: 03 at IP address 192.168.2.7.